Stage 3. Installing the MorphoAccess protective visor
Warning:
The protective visor must be installed in order to
protect the finger imaging scanner and the LCD display from
direct sunlight and dripping water.
1. Place the protective visor over the MorphoAccess and align
the four mounting holes on the visor with the four mounting
holes on the flange.
2. Re-attach the visor to the flange with the included four screws
and washers using the included hex wrench. Firmly tighten
each screw to 8 in-lb (0.90 N-m).
3. Place the provided screw caps over each screw to complete
a finished look.
4. Remove the protective film covering the LCD window.
Stage 4: Testing MorphoAccess functionality
1. Once the installation is complete, turn on the main power to
the MorphoAccess.
2. Inspect the MorphoAccess and verify that it powers up and
proceeds to the main screen.
3. Inspect the LCD and verify that the contrast and brightness
settings make the screen readable. If the LCD is not readable,
see the setup menu in the Software Guide for how to adjust
the contrast and brightness of the LCD screen.
4. Inspect the scanner and verify that the scanner is glowing
red.
5. Have the Administrator perform an enrollment and verify that
the enrollment is successful.
Note:
This step depends on the type of system configuration
and may not be appropriate for all installations.
Final installation