22
23
NOTE
: The Wiegand electrical interface conforms to the Security Industry
Association Wiegand standard (March 1995). MorphoAccess outputs 26-bit
Wiegand reverse.
NOTE
: To wire MorphoAccess for Dataclock out interface use the Wiegand
cable as follows. Green = Data Out; White = Clock Out; Black = Ground. To
configure MorphoAccess to output Dataclock (refer to pages 18-20).
NOTE
: MorphoAccess Ethernet wiring follows the T568B standard. Use a
straight-through cable between MorphoAccess and a hub. Use a crossover
cable between MorphoAccess and a PC.
Appendix 1 - Cable configuration table
Appendix 1
This table lists the cables and the function of each wire in each cable. It is
to be used as a reference to wire the Outdoor MorphoAccess for power and
interface functionality. (See diagram on Page 26 for location of the different
cables.)
Power Cable
Color
Function
White
Black
+ 12V
Ground
Wiegand Cable
Color
Function
Green
White
Brown
Black
Purple
Red
Orange
Yellow
Blue
Shield (drain)
Wiegand Out
Wiegand Out
Wiegand Out
Wiegand Out
Wiegand In
Wiegand In
Wiegand In
Wiegand In
Wiegand In
D 0
D 1
LED
GND
GND
+ 12V
LED
D 1
D 0
Not Connected