Stage 2: Positioning and preparing the MorphoAccess for final
installation against the mounting surface
1. If you haven't already done so, use the included hex wrench
to unscrew the four screws securing the MorphoAccess visor
and remove the visor. Place the visor out of the way until
needed at the end of the installation procedure.
2. Lift the MorphoAccess into position near the junction box
and place the wire stubs inside the junction box in order
to temporarily position the device against the mounting
surface.
3. Orient the MorphoAccess against the mounting surface in
the position that it will be permanently mounted with the
cable stub seals centered within the junction box without
any excessive stress applied to the cables.
4. Once you are satisfied with the location of the device against
the mounting surface, remove the backing from the gasket
material and position the sticky side of the gasket against
the backside of the MorphoAccess ensuring that the gasket
material does not cover the mounting holes.
5. Once the MorphoAccess is properly positioned against the
mounting surface, mark the location of the four fasteners at
the center of the four oval slots, cut out in the flange, that
surrounds the MorphoAccess. (See diagram on Page 5)
6. Once the four fastener locations are marked, remove the
MorphoAccess from against the mounting surface and place
in a safe location, out of the way from your work area.
7. Drill and prepare the holes for the four fasteners.
Note:
The MorphoAccess comes with four Alligator™
anchors. These anchors can be used to mount the device
to any surface, of any thickness above 1/4" (6mm).
For complete technical specifications for the Alligator
anchor please visit:
http://www.toggler.com/pdf/
alligator.pdf
Positioning and preparing the MorphoAccess