Chapter 12: Constant List
Firmware – S2011 and S3012
Revision: 1 (9/98)
89
© Saftronics, Inc.
Table 27
Constant List (Continued)
Constant
Function Name
Description
Factory
Setting
n109
∗
Slip compensation gain
Unit:
:
0.1%
Setting range :
0.0 to 9.9%
0.0%
n110
∗
Motor no-load current
Unit:
:
1%
Setting range :
0 to 99%
30%
n111
∗
Primary delay time constant
Unit
:
0.1 seconds
Setting range :
0.0 to 25.5 seconds
2.0 seconds
n112
∗
Digital Operator connection fault
detection
0
:
Connection fault detection is disabled
1
:
Connection fault detection is enabled
0
n113
∗
Frequency agree detection width
selection
Unit
:
0.1Hz
Setting range :
0.0 to 25.5Hz
2.0Hz
n114
∗
Function selection at LOCAL/REMOTE
switching
0
:
At LOCAL/REMOTE switching, restart is enabled after stop
command is input.
1
:
At LOCAL/REMOTE switching, restart is enabled at once.
0
n115
∗
kVA selection
Unit
:
1
Setting range :
GP5 (VSP2010):
0 to 8, 20 to 29
FP5 (VSP3010):
9 to F, 2A to 35
n116
CT/VT Selection
0
:
Constant Torque
1
:
VariableTorque
n117
Low Frequency OL Starting Point
Unit
:
0.1Hz
Setting range :
0.0 to 10.0Hz
6.0Hz
n118
0Hz Continuous Operation level
Unit
:
1%
Setting range :
25 to 100%
50%
∗
These constants are disabled for former softwares VSP1010 to VSP1015.
Enabled for the following software number (or after).
GP5
:
VSP2010
FP5
:
VSP3010
efesotomasyon.com - Control Techniques,emerson,saftronics -ac drive-servo motor