Ref.
Previous Ref.:
Date:
© Safran Data Systems
– IMP000074 e14r1
This document is the property of
Safran Data Systems
.
It cannot be duplicated or distributed without expressed written consent.
Page 97
ADP3 Alarm
Code
Alarm
Probable Origin
0x00000001 Board not detected
HW failure on CPU, backplane or ADP3
0x00000002 FPGA Kintex not loaded
HW failure on ADP3
0x00000004 FPGA Virtex not loaded
HW failure on CPU, backplane or ADP3
0x00000008 No license
License error (ex : serial number error)
0x00000010 10 MHz unlock
External reference not clean
0x00000020 System clock unlock
HW failure on ADP3
0x00000040 Minor temperature alarm
Θ ≤ 0°C or ≥ 80°C
0x00000080 AGC 1 link alarm
Transfer with Tuner 1 error
0x00000100 AGC 2 link alarm
Transfer with Tuner 2 error
0x00000200 Major temperature alarm
Θ ≥ 85°C
0x00000400 FPGA Kintex fan error
FAN not running if Θ > 65°C, Note : FAN is off if Θ <
55°C
0x00000800 FPGA Virtex fan error
0x40000000 Minor alarm sum
0x80000000 Major alarm sum
Tuner Alarm
Code
Alarm
Probable Origin
0x00000001 Board not detected
HW failure on CPU, backplane or Tuner
0x00000002 Board is in local mode
Board is in autonomous mode
0x00000004 Board is not calibrated
Calibration error
0x00000008 LO Alarm
Issue with 10MHz reference or HW failure
0x00000010 Synthesizer alarm
Issue with 10MHz reference or HW failure
0x00000020 Minor temperature alarm
Θ ≤ 0°C or ≥ 80°C
0x00000040 Major temperature alarm
Θ ≥ 85°C
0x40000000 Minor alarm sum
0x80000000 Major alarm sum
Multiband Alarm
Code
Alarm
Probable Origin
0x00000001 Board is in local mode
Board is in autonomous mode
0x00000002 Board is not calibrated
Calibration error
0x00000004 LO Alarm 1
Issue with 10MHz reference or HW failure
0x00000008 LO Alarm 2
Issue with 10MHz reference or HW failure
0x40000000 Minor alarm sum
0x80000000 Major alarm sum