Ref.
Previous Ref.:
Date:
© Safran Data Systems
– IMP000074 e14r1
This document is the property of
Safran Data Systems
.
It cannot be duplicated or distributed without expressed written consent.
Page 93
6.
TCP/IP or UDP/IP frame setup with Reed Solomon FEC (Soyuz)
Path
: [
HKLM\SOFTWARE\IN-SNEC\rtrnt\common\fec\rs_soyouz
]
Register Key
Type
Description / Default Value
SyncWordEnable
DWORD
RS Frame Sync Word transmission :
0 : disable
1 : enable (Default)
CheckSymbEnable
DWORD
RS Check symbols transmission:
0 : disable
1 : enable (Default)
SyncWord
DWORD
RS syncword
Defaut : 0x1ACFFC1D
7.
TCP/IP or UDP/IP frame setup with TPC FEC
Path
: [
HKLM\SOFTWARE\IN-SNEC\rtrnt\common\fec\tpc
]
Register Key
Type
Description / Default Value
SyncWordEnable
DWORD
RS Frame Sync Word transmission :
0 : disable
1 : enable (Default)
CheckSymbEnable
DWORD
RS Check symbols transmission:
0 : disable
1 : enable (Default)
8.
IRIG-B Setup
Path
: [
HKLM\SOFTWARE\IN-SNEC\rtrnt\common\irig
]
Register Key
Type
Description / Default Value
att_in_enabled
DWORD
Attenuation on the IRIG-B input:
0 : attenuation off
1 : attenuation on (Default)
enabled
DWORD
IRIG-B time processing:
0 : disable
1 : enable (Default)
auto_leap_year
DWORD
Automatic bissextile year adjustement:
0 : disable
1 : enable (Default)
update_sys
DWORD
System Time updated with IRIG-B time:
0 : disable
1 : enable (Default)