26
②
Command Function: Set leaving time
Command Grammar: 3 5 # D D #
Function Description: “D D” refers to leaving time, also called delayed ARM
time and must be a 2-digit number (00-99 minutes). Within the leaving period of
time, the alarm host gives out a short “Beep” sound every 1 second, and you must
leave defense zones during the time period.
Operating Steps: “###”
(
Please enter the preset password
)
+“112233#”
(
The
host enters into adjusting mode
)
+“35#”
(
Please enter leaving time
)
+“05#”
(
The host
gives out a voice prompt “Ding” to indicate leaving time has been successfully set
up
)
.
③
Command Function: Set Entry Time
Command Grammar: 3 6 # D D #
Function Description: “D D” refers to entry time, also called delayed alarm
time and must be a 2-digit number (00-99 seconds). If you break into an armed
defense zone, the alarm host does not sound an alarm when you disarm the defense
zone by remote control or phone for local calls within the entry period of time. If
you do not disarm the defense zone within the entry period of time, the alarm host
will automatically sound an alarm once the pre-set entry time expires. Within the
entry period of time, the alarm host gives out a “Beep” sound every 1 second.
Operating Steps: “###”
(
Please enter the preset password
)
+“112233#”
(
The
host enters into adjusting mode
)
+“36#”
(
Please enter entry time
)
+“00#”
(
The host
gives out a voice prompt “Ding” to indicate entry time has been successfully set up
)
.
④
Command Function: Set ringing times
Command Grammar: 3 7 # D D #
Function Description: “D D” refers to ringing times (05-15) within which the
host can automatically pick up the call.
Operating Steps: “###”
(
Please enter the preset password
)
+“112233#”
(
The
host enters into adjusting mode
)
+“37#”
(
Please enter ringing times
)
+“09#”
(
The
host gives out a voice prompt “Ding” to indicate ringing times has been successfully
set up
)
.