24
Press 2 5 # to select the medium on-site alarm volume;
Press 2 6 # to select the large on-site alarm volume
Press 2 7 # to select the maximum on-site alarm volume
Operating Steps: “###”
(
Please enter the preset password
)
+“112233#”
(
The host
enters into adjusting mode
)
+“27#”
(
for trial listening of alarm volume
of the host
)
.
Note: Once this set-up is finished, the preset alarm volume will be automatically
modified.
②
Command Function: Set on-site alarm volume to mute
Function Description: If on-site alarm volume is set to mute, in phone alarm
mode, the horn can not sound an alarm, and the alarm sound output
terminal can not output alarm sound, but informed user phone
numbers can be dialled to transmit alarm information, and a normal
prompt sound is given out when a remote controller is working, an
alarm occurs due to phone line cut-off, or the power supply voltage
is too low.
Note:
a. When alarm volume is set to any level in accordance with the last step, the
mute function will be automatically cancelled.
b. Mute alarm is only applicable to phone alarm mode, because there is no
mute function in on-site alarm mode.
6. Record
①
Command
Command
Command
Command Function:
Function:
Function:
Function: Record
Record
Record
Record
Command Grammar: 3 0 # Record #
Function Description: Press 3 0 #, and then
“
RECORD
”
Indicator on the
keyboard panel lights up. Speak into the microphone built into the
alarm host cabinet to record your desired voice (Recording time is 2-3
seconds). The previously recorded voice message will be replaced by
newly recorded voice message, and the newly recorded content can be
stored permanently and is not lost when power supply is cut off.