15
The first four steps of deleting a remote controller are the same as those of
adding a remote controller.
Step 5: Enter 19 and # after 19, and then the host gives out a voice prompt
“Delete all remote controllers”.
Step 6: Press “#” key again, and then the host gives out a voice prompt
“Ding”, which means a remote controller is successfully deleted.
(I)
(I)
(I)
(I)
Add/Delete
Add/Delete
Add/Delete
Add/Delete Detectors
Detectors
Detectors
Detectors
The host can learn codes with 120 detectors. There are 120 defense zones
(numbered 000-119), among which defense zone 000 is a tamper zone intended for
the host, and defense zones 000-007 are mixed wired/wireless defense zones in
which it is not recommended to install wireless detectors.
To add/delete detectors and modify attributes of defense zones with detectors,
please follow the following procedures:
1.
Add
Add
Add
Add Detectors
Detectors
Detectors
Detectors (Take
(Take
(Take
(Take Defense
Defense
Defense
Defense Zone
Zone
Zone
Zone 010
010
010
010 for
for
for
for example)
example)
example)
example)
Step 1: Enter “# # #”, and then the host gives out a voice prompt “Please enter a
pre-set password”.
Step 2: Enter password “112233” and “#” after password, and then the alarm host
gives out a voice prompt
“
The alarm host is entering into adjustment mode
”
(“112233” is a factory default password for the host and can be modified. ).
Step 3:
Set the host when “SET” indicator of the host lights up.
Step 4:
Enter “12*48 ” and “#” after password, and then the alarm host gives out a
voice prompt “The alarm host is entering into code learning mode” (Note: The
host interface will display “b” when you enter “*”. ).
Step 5:
Enter “010” (defense zone No.) and “#” after 010, and then the host gives
out a voice prompt “Now, the host is serving a fully armed zone. Please activate
a detector” (After a voice prompt, the detector will be activated, and then the
host will give out a voice prompt “Ding”, which means the detector is
successfully added).
To continue to add a detector, for example a detector for defense zone 011,
please enter “011” and “#” after 011.