Electrical Installation
7. Connect the line end of the cable as follows:
For truck installation:
(Figure 34)
.
7.1. Mount the circuit breaker as close to the truck
battery as possible.
7.2. Mount the master disconnect switch in the cab
where the driver can reach it.
7.3. Cut the cable at the master disconnect switch and
circuit breaker positions. Prepare the cable ends per
Steps 3 and 4.
NOTE:
Ensure the master disconnect switch is in the
“OFF” position prior to connecting the battery.
7.4. Connect the cable to the master disconnect switch,
circuit breaker, and battery.
For truck installation:
(Figure 35)
.
7.1. Mount the connector to the front of the trailer
adjacent to the airline connections.
7.2. Cut the cable at the connector position and prepare
the cable end per Steps 3 and 4.
7.3. Attach the cable to the connector.
IMPORTANT:
Verify that the tractor's electrical system
is properly designed to protect the liftgate
and tractor from overload.
MASTER DISCONNECT
SWITCH
BATTERY GROUNDED
BATTERY
CIRCUIT BREAKER
OR IN-LINE FUSE
MOTOR GROUNDED
PUMP BOX
MOTOR GROUNDED
TO PUMP MOTOR
SOLENOID
SINGLE POLE
CONNECTOR