EN
DIGIWAVE
III
15
MIG WELDING PAGE
you are allowed to weld only if the color of the top left icon is green
.
1
Arc current measure
2
Arc voltage measure
3
Wirespeed
4
Motor current of the wire feeder
5
Welding time (includes all the steps of the welding cycle)
The motor current of the wire feeder is proportional to the motor torque. Beyond 1.3A at constant regime, check that the wire feeder liner is not
clogged with dirt.
The previous welding parameters are accessible on the SETUP page from the MIG-MAG menu.
If "call off the trigger program welding" is not active: Short press the trigger vacuum (if program change).