DISPLAY OF THE MESSAGE E30 “Boot Failure”
Only in AUTOMATIQUE mode
time out of 3 seconds Effective Detecting the welding launch without striking
DISPLAY OF THE MESSAGE E32 “Broken arc”
Only in AUTOMATIQUE mode
break detection arc
DISPLAY OF THE MESSAGE E33 “Job problem”
Calling a non existing program or unauthorized
The program is not compatible with this software version
The configuration is not compatible with this software version
A program is corrupt :
This program is visible in the list of programs on the screen on the front
of the generator.
The system configuration is corrupted
A list of programs is corrupted
Please update the software generator.
Please update the software generator.
Suppression program is necessary
Parametrage a new installation is required.
Please reconfigure the program listings
DISPLAY OF THE MESSAGE E42 «
stable supply
»
The power supply is unstable
please check your electrical system
DISPLAY OF THE MESSAGE E44 “Harness calibration problem”
Impossible to finalize the automatic calibration.
Check that the calibration procedure displayed on the screen is well
respected
DISPLAY OF THE MESSAGE E45 « order immediate stop welding»
Demand immediate cessation of welding user
DISPLAY OF THE MESSAGE E49 « Check Device Connection»
More communication with a device
Check the device connection displayed
It is imperative to connect and disconnect the device when the system is off
DISPLAY OF THE MESSAGE E50 “Cooling problem”
Problem of pressure or flow of cooling unit
DISPLAY OF THE MESSAGE E52 “Stuck electrode”
MMA only :
Detection of stuck wire on the piece.
Unstick the electrode
DISPLAY OF THE MESSAGE E53 “Stuck wire”
MIG only
Detection of the sticking of the wire in the workpiece.
Cut the wire
DISPLAY OF THE MESSAGE E63 « Excess torque reeling»
Excessive engine torque unwinding
check that the sheath of the wire is not encrasse and that nothing prevents the
movement of the thread and the movement of the wire feed
DISPLAY OF THE MESSAGE E72 “Not present synergy”
Launch welding program whose synergy user is not present in the welding
generator
import or define the corresponding user synergy current program
DISPLAY OF THE MESSAGE E80 « Detection Process Control I min »
Overflow monitoring threshold low welding current user-defined
DISPLAY OF THE MESSAGE E81
« Detection Process control I max
»
Overflow monitoring threshold low welding current user-defined
DISPLAY OF THE MESSAGE E82
« U min Detection Process Control »