22
Keep the manual for future reference - For more informations visit www.saerelettropompe.com
HANDLING
General provisions
•
Use suitable means for lifting and transporting the pump / electricpump: it may be damaged if it is knocked or
if it falls, even if there is no apparent external damage, and it may also damage things or persons.
•
Use ropes, straps or chains suitable for the purpose: for the weights of the complete set or of the individual
components (pump, motor ...), refer to the drawings and technical documentation. If necessary, contact the
technical support service.
•
Make sure that the lifting means adopted have a capacity adequate to the load to be lifting and that they are
in good condition.
•
Do not pause or pass under the load during lifting or transport.
•
Always comply with general and local regualtions in force.
•
The pump is supplied packed in protective packaging which must be removed just before installation.
•
Appropriate measures must be taken to prevent contamination of materials and articles themselves, in order
not to deteriorate the water quality post then in contact with them.
STORING
WARNING!
•
Storage conditions: store the pump / set in a covered and dry place, lacking dust, freeze and vibrations.
•
Storage temperature= min 0°C - max 50°C
•
Metallic exposed surfaces (flanges) must be protected in a suitable way to prevent corrosion.
•
If you plan to store the pump or the complete set, for a long period of time (more than one month), it is
necessary to perform the following operations monthly:
o
Verify that the preservation status of the pump / complete set and paying more attention to the
non-painted surfaces;
o
Check with the appropriate tools, the free rotation of the shaft;
o
Once a month, rotate shaft by hand, in order to keep the bearings protected by the lubricant.
o
For any problem replace or recondition the damages parts prior the use.
4. TECHNICAL SPECIFICATIONS AND USE
PRODUCT DESCRIPTION
IR:
Close-coupled end-suction electricpumps according to EN733
MG1:
Close-coupled end-suction pumps according to EN733 with stab shaft
MG2:
Close-coupled end-suction electricpumps according to EN733 with stab shaft
Sizes up to DN65: one-piece construction with the pump shaft / single motor.
Sizes DN80 and bigger : normalized motor mounting position V1, coupled to the pump through the shaft coupling of the pump.
“Back pull out” system: the hydraulic part can be removed without removing the pump body from the piping.
Horizontal or vertical installation (always with the motor upwards).
Hydraulic seal: mechanical seal with single spring.
Closed impeller with several rooms.
Ball bearings, permanent grease lubrication.
Motors: asynchronuos induction fan cooled electric motors (TEFC)
Standard voltages:
• Frequency 50 Hz: 1~: 220-240V up to 4 kW; 3~: 220-240/380-415V up to 4 KW and 380-415V / 660-720V starting from 5,5 kW.
• Frequency 60 Hz: 1~: 220V up to 4 kW; 3~: 220/380 V or 255-278/440-480 V up to kW 4; 380/660 V or 440-480/760-
830V starting from 5,5 kW. Allowable voltage variation: ± 5% Un
Motor protection against overloads: protections have to be provided by the customer (see paragraph 5).
Degree of protection (IP) and insulation class: Refer to the motor nameplate.
The pump / electric pump’s identification and technical data are listed on the name plate which certify the conformity to CE norms
(FIG.1
).
Summary of Contents for IR
Page 61: ...61 www saerelettropompe com 1 2 4 3...
Page 63: ...63 www saerelettropompe com o o SAER I EN809 5...
Page 64: ...64 www saerelettropompe com 5 SAER 40 C 40 C 1000 3 160 NPSH NPSH NPSH...
Page 66: ...66 www saerelettropompe com Y 3 6 i ii iii 4 iv v vi i ii 4 iii iv v 1 2 3...
Page 67: ...67 www saerelettropompe com 40 C 90 C 50 C PN 10 7 o o o o o o...
Page 68: ...68 www saerelettropompe com 1500 90 C o 3000 II L10 8 8...
Page 74: ...74...
Page 75: ...75...