Test Mode INTELIA EVO V2 AMF
Filename
Intelia_EVO2_AMF_TestMode_V05
5.0
G Divella
12/06/2015
9/12
revNum Author
Verified
Approved
SaveDate P/PP
1.5 Page 4 (EV - PUMP)
Should this page been shown it means either the dreg drawer is not
correctly inserted or the side door not closed. Only solving both these
issues it would be possible to come out from this screen.
Press the
ESPRESSO
button to activate the 2-ways
Electrovalve
(closed by default)
The Electrovalve is activated so the
EV1
value turns from “OFF” to
“ON”.
Press the
HOT WATER
button to activate the
Pump
The water now flows out from the spout, causing the update of the
IMP
value with the number of flowmeter impulses. The
L/H
value
must stay within 10l/h and 18 l/h.
ERROR:
If the number of impulses remains 0 and the display backlight turns
red, it means that there’s an error in the hydraulic circuit. If water
comes out from the spout it means that there’s an error in the
flowmeter or in its wiring to the CPU/POWER (JP5); if, on the other
hand, no water comes out it’s necessary to check the pump or the
hydraulic circuit, or the pump wiring (JP24).
Press the
STEAM WATER
button
The CA shows the Heater/Grinder page (Heater-Grinder)
1.6 Page5 (Heater-Grinder)
Test Mode INTELIA EVO V2 AMF
Filename
Intelia_EVO2_AMF_TestMode_V05
5.0
G Divella
12/06/2015
9/12
revNum Author
Verified
Approved
SaveDate P/PP
1.5 Page 4 (EV - PUMP)
Should this page been shown it means either the dreg drawer is not
correctly inserted or the side door not closed. Only solving both these
issues it would be possible to come out from this screen.
Press the
ESPRESSO
button to activate the 2-ways
Electrovalve
(closed by default)
The Electrovalve is activated so the
EV1
value turns from “OFF” to
“ON”.
Press the
HOT WATER
button to activate the
Pump
The water now flows out from the spout, causing the update of the
IMP
value with the number of flowmeter impulses. The
L/H
value
must stay within 10l/h and 18 l/h.
ERROR:
If the number of impulses remains 0 and the display backlight turns
red, it means that there’s an error in the hydraulic circuit. If water
comes out from the spout it means that there’s an error in the
flowmeter or in its wiring to the CPU/POWER (JP5); if, on the other
hand, no water comes out it’s necessary to check the pump or the
hydraulic circuit, or the pump wiring (JP24).
Press the
STEAM WATER
button
The CA shows the Heater/Grinder page (Heater-Grinder)
1.6 Page5 (Heater-Grinder)
Test Mode INTELIA EVO V2 AMF
Filename
Intelia_EVO2_AMF_TestMode_V05
5.0
G Divella
12/06/2015
9/12
revNum Author
Verified
Approved
SaveDate P/PP
1.5 Page 4 (EV - PUMP)
Should this page been shown it means either the dreg drawer is not
correctly inserted or the side door not closed. Only solving both these
issues it would be possible to come out from this screen.
Press the
ESPRESSO
button to activate the 2-ways
Electrovalve
(closed by default)
The Electrovalve is activated so the
EV1
value turns from “OFF” to
“ON”.
Press the
HOT WATER
button to activate the
Pump
The water now flows out from the spout, causing the update of the
IMP
value with the number of flowmeter impulses. The
L/H
value
must stay within 10l/h and 18 l/h.
ERROR:
If the number of impulses remains 0 and the display backlight turns
red, it means that there’s an error in the hydraulic circuit. If water
comes out from the spout it means that there’s an error in the
flowmeter or in its wiring to the CPU/POWER (JP5); if, on the other
hand, no water comes out it’s necessary to check the pump or the
hydraulic circuit, or the pump wiring (JP24).
Press the
STEAM WATER
button
The CA shows the Heater/Grinder page (Heater-Grinder)
1.6 Page5 (Heater-Grinder)
Test Mode INTELIA EVO V2 AMF
Filename
Intelia_EVO2_AMF_TestMode_V05
5.0
G Divella
12/06/2015
9/12
revNum Author
Verified
Approved
SaveDate P/PP
1.5 Page 4 (EV - PUMP)
Should this page been shown it means either the dreg drawer is not
correctly inserted or the side door not closed. Only solving both these
issues it would be possible to come out from this screen.
Press the
ESPRESSO
button to activate the 2-ways
Electrovalve
(closed by default)
The Electrovalve is activated so the
EV1
value turns from “OFF” to
“ON”.
Press the
HOT WATER
button to activate the
Pump
The water now flows out from the spout, causing the update of the
IMP
value with the number of flowmeter impulses. The
L/H
value
must stay within 10l/h and 18 l/h.
ERROR:
If the number of impulses remains 0 and the display backlight turns
red, it means that there’s an error in the hydraulic circuit. If water
comes out from the spout it means that there’s an error in the
flowmeter or in its wiring to the CPU/POWER (JP5); if, on the other
hand, no water comes out it’s necessary to check the pump or the
hydraulic circuit, or the pump wiring (JP24).
Press the
STEAM WATER
button
The CA shows the Heater/Grinder page (Heater-Grinder)
1.6 Page5 (Heater-Grinder)
Test Mode INTELIA EVO V2 AMF
Filename
Intelia_EVO2_AMF_TestMode_V05
5.0
G Divella
12/06/2015
9/12
revNum Author
Verified
Approved
SaveDate P/PP
1.5 Page 4 (EV - PUMP)
Should this page been shown it means either the dreg drawer is not
correctly inserted or the side door not closed. Only solving both these
issues it would be possible to come out from this screen.
Press the
ESPRESSO
button to activate the 2-ways
Electrovalve
(closed by default)
The Electrovalve is activated so the
EV1
value turns from “OFF” to
“ON”.
Press the
HOT WATER
button to activate the
Pump
The water now flows out from the spout, causing the update of the
IMP
value with the number of flowmeter impulses. The
L/H
value
must stay within 10l/h and 18 l/h.
ERROR:
If the number of impulses remains 0 and the display backlight turns
red, it means that there’s an error in the hydraulic circuit. If water
comes out from the spout it means that there’s an error in the
flowmeter or in its wiring to the CPU/POWER (JP5); if, on the other
hand, no water comes out it’s necessary to check the pump or the
hydraulic circuit, or the pump wiring (JP24).
Press the
STEAM WATER
button
The CA shows the Heater/Grinder page (Heater-Grinder)
1.6 Page5 (Heater-Grinder)
Test Mode INTELIA EVO V2 AMF
Filename
Intelia_EVO2_AMF_TestMode_V05
5.0
G Divella
12/06/2015
9/12
revNum Author
Verified
Approved
SaveDate P/PP
1.5 Page 4 (EV - PUMP)
Should this page been shown it means either the dreg drawer is not
correctly inserted or the side door not closed. Only solving both these
issues it would be possible to come out from this screen.
Press the
ESPRESSO
button to activate the 2-ways
Electrovalve
(closed by default)
The Electrovalve is activated so the
EV1
value turns from “OFF” to
“ON”.
Press the
HOT WATER
button to activate the
Pump
The water now flows out from the spout, causing the update of the
IMP
value with the number of flowmeter impulses. The
L/H
value
must stay within 10l/h and 18 l/h.
ERROR:
If the number of impulses remains 0 and the display backlight turns
red, it means that there’s an error in the hydraulic circuit. If water
comes out from the spout it means that there’s an error in the
flowmeter or in its wiring to the CPU/POWER (JP5); if, on the other
hand, no water comes out it’s necessary to check the pump or the
hydraulic circuit, or the pump wiring (JP24).
Press the
STEAM WATER
button
The CA shows the Heater/Grinder page (Heater-Grinder)
1.6 Page5 (Heater-Grinder)
Test Mode INTELIA EVO V2 AMF
Filename
Intelia_EVO2_AMF_TestMode_V05
5.0
G Divella
12/06/2015
10/12
revNum Author
Verified
Approved
SaveDate P/PP
Initial condition
Press the
HOT WATER
button to activate the
Grinder
The coffee grinder starts milling for 5000 ms, if the user doesn’t
release the button before. In this case the activation time is shown in
the red-circled field of the picture
ERROR:
If this number keeps fixed at 0, the display turns red and the engine
moves, then there must be a fault in the grinder wiring (JP8), or in
the grinder itself.
Keep pressed
STANDBY
for 5 secs to
reset
grinder parameters
Pressing button STANDBY for 5 secs resets grinder parameters
Test Mode INTELIA EVO V2 AMF
Filename
Intelia_EVO2_AMF_TestMode_V05
5.0
G Divella
12/06/2015
10/12
revNum Author
Verified
Approved
SaveDate P/PP
Initial condition
Press the
HOT WATER
button to activate the
Grinder
The coffee grinder starts milling for 5000 ms, if the user doesn’t
release the button before. In this case the activation time is shown in
the red-circled field of the picture
ERROR:
If this number keeps fixed at 0, the display turns red and the engine
moves, then there must be a fault in the grinder wiring (JP8), or in
the grinder itself.
Keep pressed
STANDBY
for 5 secs to
reset
grinder parameters
Pressing button STANDBY for 5 secs resets grinder parameters
Test Mode INTELIA EVO V2 AMF
Filename
Intelia_EVO2_AMF_TestMode_V05
5.0
G Divella
12/06/2015
10/12
revNum Author
Verified
Approved
SaveDate P/PP
Initial condition
Press the
HOT WATER
button to activate the
Grinder
The coffee grinder starts milling for 5000 ms, if the user doesn’t
release the button before. In this case the activation time is shown in
the red-circled field of the picture
ERROR:
If this number keeps fixed at 0, the display turns red and the engine
moves, then there must be a fault in the grinder wiring (JP8), or in
the grinder itself.
Keep pressed
STANDBY
for 5 secs to
reset
grinder parameters
Pressing button STANDBY for 5 secs resets grinder parameters
GAGGIA VELASCA 05 SERVICE MODE
5/8
1.5 Page 4 (EV - PUMP)
Press the ESPRESSO button to activate the 2-ways Electrovalve (closed by default)
The Electrovalve is activated so the EV1 value turns from “OFF” to “ON”.
Press the HOT WATER (Press MILK for OTC version) button to activate the Pump
The water now flows out from the spout, causing the update of the IMP
value with the number of flowmeter impulses. The L/H value must stay
within 10l/h and 18 l/h.
ERROR:
If the number of impulses remains 0 and the display backlight turns red,
it means that there’s an error in the hydraulic circuit. If water comes out
from the spout it means that there’s an error in the flowmeter or in its
wiring to the CPU/POWER (JP5); if, on the other hand, no water comes
out it’s necessary to check the pump or the hydraulic circuit, or the pump
wiring (JP24).
Press the STEAM WATER button (Press CAPPUCCINO for OTC version)
The CA shows the Heater/Grinder page (Heater-Grinder)
Initial condition
Press the HOT WATER (Press MILK for OTC version) button to activate the Grinder
The coffee grinder starts milling for 5000 ms. In this case the activation
time is shown in the red-circled field of the picture
ERROR:
If this number keeps fixed at 0,or the grinder does not run, the display
turns red: this means there must be a fault in the grinder wiring (JP8), or
in the grinder itself, or in the electronic board.
Keep pressed STANDBY for 5 secs to reset grinder parameters
Pressing button STANDBY for 5 secs resets grinder parameters:
This action is needed if the grinder has been replaced.
Should this page been shown it means either the dreg drawer is not cor
-
rectly inserted or the side door not closed. Only solving both these issues
it would be possible to come out from this screen.
1.6 Page 5 (Heater-Grinder)
Summary of Contents for GAGGIA VELASCA CMF-OTC
Page 3: ...GAGGIA VELASCA CHAPTER 1 INTRODUCTION...
Page 10: ...GAGGIA VELASCA CHAPTER 2 TECHNICAL SPECIFICATIONS...
Page 16: ...GAGGIA VELASCA CHAPTER 3 BRIEF INSTRUCTIONS...
Page 23: ...GAGGIA VELASCA CHAPTER 4 OPERATING LOGIC...
Page 31: ...GAGGIA VELASCA CHAPTER 5 SERVICE MODE...
Page 40: ...GAGGIA VELASCA CHAPTER 6 SERVICING AND MAINTENANCE...
Page 43: ...GAGGIA VELASCA CHAPTER 7 DISASSEMBLY...
Page 50: ...GAGGIA VELASCA CHAPTER 8 NOTES...
Page 51: ...GAGGIA VELASCA 08 NOTES 1 1...
Page 52: ...GAGGIA VELASCA CHAPTER 9 WATER CIRCUIT DIAGRAM...
Page 54: ...GAGGIA VELASCA CHAPTER 10 ELECTRICAL DIAGRAM...
Page 55: ...GAGGIA VELASCA 10 ELECTRICAL DIAGRAM 1 1 10 1 Electrical diagram...