60
English
Cause
Code
Message
Registered in
Effect
Error
Automatic
Error
ERROR LOG
resettable
reset at
resettable
as error
by means of
restarting
from
or warning
“Automatic
5-key
Reset”
keypad
procedure
water level low in air break
1
“ NO WATER 01”
W/E
blocked
YES*
YES
YES
no coffee dosing unit level detected
(coffee not available?)
2
“COFFEE NOT AVAILABLE”
E
coffee blocked
YES
NO
YES
no movement of group gearmotor detected
3
“BREWING UNIT BLOCK03”
E
coffee blocked
YES*
YES
YES
no movement of group gearmotor detected
4
“BREWING UNIT BLOCK04”
E
coffee blocked
YES*
YES
YES
no flowmeter pulses detected
5
“ NO FLOWMETER 05”
E
blocked
NO
NO
YES
no movement of dispensing arm detected
6
“ ARM DISP. BLOCKED06”
E
blocked
NO
YES
YES
no movement of dispensing arm detected
7
“ ARM DISP. BLOCKED07”
E
blocked
NO
NO
YES
no cups detected
8
“ NO CUPS 08”
E
blocked
—-
YES
YES
drip tank full
9
“DRIP TANK FULL 09”
E
blocked
YES*
YES
YES
no movement of cup release detected
10
“ CUP DISP. BLOCKED10”
E
blocked
YES*
YES
YES
no movement of stirrer ejector detected
11
“SPOON DISP. BLOCKED “
E
blocked
NO
NO
YES
no movement of stirrer ejector detected
12
“SPOON DISP. BLOCKED “
E
blocked
NO
NO
YES
reading of temperature sensor out of range
13
“TEMP. SENSOR ERROR13”
E
blocked
NO
YES
YES
reading of coffee temperature sensor out of range
14
“TEMP. SENSOR ERROR14”
E
blocked
NO
YES
YES
e2prom corrupted
16
“ E2CHECK ERROR 16”
E
blocked
NO
YES
YES
no movement of cup holder detected
17
“BASKET CUP BLOCKED17”
E
blocked
NO
NO
YES
no brew group detected
20
“ BREWING UNIT N/A 20”
E
coffee blocked
YES*
YES
YES
no dreg drawer detected
21
——
E
—-
YES
YES
abnormal flow detected in coffee brewing
22
“ ABNORMAL FLOW 22”
W/E
coffee blocked
YES
NO
YES
pump timeout
23
“ PUMP TIMEOUT 23”
W
message only
YES
no instant product boiler level detected
24
“BOILER FILLING ERR24”
E
blocked
—-
—-
YES
Saeco card without timekeeper detected
25
“ TIMEKEEPER REQUIRED”
E
blocked
NO
YES
YES
setting of decimal point position detected not
consistent with payment system
31
“DECIMAL POINT ERROR “
E
blocked
NO
YES
YES
credit management restarting message
32
——
E
message only
—-
—-
YES
pressing of CPU P3 key for 15 seconds detected
33
“ OUT OF SERVICE 33”
E
blocked
NO
NO
YES
Normal operation restored message after
abnormal flow
34
——
W
message only
—-
—-
YES
MDB slave error detected
35
——
W
message only
YES
coffee boiler heating slow
36
“ BOILER1 ERROR 36”
E
blocked
NO
YES
YES
instant product boiler heating slow
37
“ BOILER2 ERROR 37”
E
blocked
NO
YES
YES
CRC flash error
38
“ CRC ERROR 38”
E
blocked
NO
NO
NO
BDV message
41
——
E
message only
—-
—-
—-
watchdog intervention
72
——
YES
message only
change-giving coiner error message
80
——
YES
message only
—-
—-
—-
GSM modem error message
81
——
YES
message only
—-
—-
—-
boiler triac overtemperature detected
82
——
YES
message only
—-
—-
—-
Summary of Contents for CRISTALLO 600
Page 63: ...63 English...
Page 64: ...Cod 15001063 Ed 00 03 07...