46
English
CONTINUES
RINSING
CRISTALLO 400
PLEASE WAIT
BOILER COOLING
DRAIN BOILER
DRAIN BOILER
>Y< N
SOLUBLES
TEST WATER/SOLUBLES
WATER
1- error code (or warning code) occurred;
2- location of signal source (e.g., which spiral motor,
if the error is due to a spiral motor, or which coffee or
instant product);
3- day, month, hour and minute of error detection (this
information is available only if the VM is equipped with
a timekeeper).
The recordings are included in a list which may contain
up to 50 elements; when this limit is exceeded the
information is input again starting from position 1
(previous information will be lost).
Note
All errors or faults are stored, except when blocks occur
(coffee, instant product, beverage, water).
Display:
ERROR LOG ii/NN
Exx aabb ddmmm hh:mm
Format of warning error description recorded in LOG:
Exx
WHAT ==> xx code error/warning alarm
aabb
WHERE==> if Myy = spiral motor yy
aabb
WHERE==> if Syy = yy instant product dispensing
aabb
WHERE==> if Lyy = yy instant product rinsing
aabb
WHERE==> if C — = coffee brewing
aabb
WHERE==> if aabb = hexadecimal codes
ddmmm
WHEN==> day in figures, month in string (3
letters)
hh:mm
WHEN==> hour:minutes
ii
error index in LOG
NN
number of errors in LOG
- Rinsing
Enables rinsing of the instant product brewing circuits.
By pressing the ENTER key the automatic cycle starts,
thus activating each instant product circuit in sequence.
Recommended solutions
To rinse the circuit of a single instant product it is necessary
to keep the beverage keys pressed:
- Beverage key 2: instant 1 rinsing
- Beverage key 3: instant 2 rinsing
- Beverage key 4: instant 3 rinsing
- Test Water/Instant product
Instant product check:
It enables the selection of
one of the instant product dispensing motors available
on the vending machine, and to actuate it for 5 seconds,
so that its capacity can be checked.
Water check:
It enables the selection of one of the
solenoid valves available on the vending machine, and
to actuate it for 10 seconds, so that its capacity can be
checked.
- Boiler Cooling
Allows quick cooling of the boiler.
By selecting the item “ BOILER COOLING “ the VM
dispenses water until the temperature detected by the
sensor placed on the boiler has fallen below 50°C.
A coloured bar on the display indicates the current
temperature of the boiler. When the bar disappears the
temperature detected is less than 50° and the cooling
down operation is completed; the VMC must be turned
off.
- Boiler emptying
It enables start-up of the automatic discharge cycle of
the boiler.
Summary of Contents for CRISTALLO 600
Page 63: ...63 English...
Page 64: ...Cod 15001063 Ed 00 03 07...