How to finish testing the door and the safety features
Navigate to parameter P:980 and set the value
to 4 so the door will cycle continuously
Do This
Result
1
The default value is 0.
2
You can now change the value.
3
4
The new value is saved.
5
6
1
Watch
the door as it cycles.
▪
Make sure
the door panel rises to the fully open
position, remains in place for the standard time,
then closes to the fully closed position.
▪
Make sure
the fully open and fully closed positions
remain at the set limits.
▪
Make sure
the reversing edge is level when the
door is fully closed.
▪
Let the ACL timer
hold the door open
through each cycle. Shortening the timer
while the door is cycling can cause the
motor to overheat.
2
While the door cycles,
look and listen
for:
▪
Unusual noises
such as grinding, whining or
excessive motor noise
▪
Excess movement
by the motor, drive or drum.
□
Unexpected delay
in activation or unusually long
time period before automatically closing.
3
Make sure
the blue LED
a
(receiver) and green
LED
b
(transmitter) on the Advanced
3
light
curtains are flashing once every two second,
and that the red LED
c
(receiver) and yellow
LED
c
(transmitter) are
OFF
.
If the red light and yellow lights are on,
or if you see
a different combination of lights, call Rytec technical
support at
800-628-1909
.
PDN-UI-000057
980=
0
#
P:Operat.Mode
S
until parameter displays
PDN-UI-000052
1x
to move cursor to the right (edit value)
980=
0
#
P:Operat.Mode
S
PDN-UI-000059
4x
to change the value to 4
980=
4?#
P:Operat.Mode
S
PDN-UI-000060
until question mark changes to
checkmark (value saved)
980=
4
#
P:Operat.Mode
S
PDN-UI-000060
until door returns to run mode
Spiral
[xxx] Cycles
RY-FT-000092
press either arrow to start cycling
5
Sec
Acl
1
Receiver
Transmitter
a
c
b
d
If the red LED is on,
run a laser level on the
vertical guide track to
make sure the light
curtains are at
the same height.
Adjust
if necessary.
Laser level
4
Test the Advanced
3
light curtains
by placing your hand flat
across any of the light
curtains at the top
a
,
middle
b
and bottom
c
while the door panel closes.
Make sure
the door panel
stops quickly if the door
panel is close to your
hand, more gradually
if the panel is farther up
the door track.
Make sure
the door panel
returns to the fully open
position each time the light
curtain is activated.
5
Test the SmartSurround™
system:
▪
Make sure
the light curtains
flash rapidly whenever either
of the planes are broken.
▪
If one plane is broken but
the other is not,
the light
curtains should reverse/
hold the door, then the door
should count down and
descend at creep speed.
▪
If all planes are broken,
the
light curtains should reverse/
hold the door, then the door
should count down and
descend at normal speed.
6
LEDs on the CAN repeaters and distributor
indicate if the system is working correctly
a
LEDs next to the ports
(blue)
should be ON
steadily (no flashing).
b
The CAN status LED
(yellow)
should be
flashing one to four
times per second.
c
The power status LED
(green)
should be ON
steadily (no flashing).
Contact technical support
if you do not see this.
7
If the door has an active reversing edge
(optional), test
the reversing edge by placing your
arm in the path of the door while it is closing.
Make sure
you place your arm
above the light curtains.
The door panel should stop,
then reverse
direction and rise to the fully open position.
8
Set the controller
to parameter mode.
Set Parameter 980 back to 0
to take the door
out of continuous cycle.
Return
to run mode.
9
Activate
the door using each activating
system at least three times per system.
a
b
c
a
a
b
c
b
c
WARNING
Make sure you are standing clear
of the