Spiral
®
SST and STT Prewire Installation Manual
Spiral
®
SST and STT Prewire Installation Manual
■
1072124-0
■
Rev 03
■
01/22
11
6
Remove
the bolts and
move
the bracket and CAN terminal to allow access to all anchor holes
a
,
b
,
c
.
Make sure
you do not disconnect any cables when moving the bracket.
Leave the brackets loose
until the installation is complete.
See
How to install the wall mounted (rear) SmartSurround™ light curtains
on page 21.
Do this
on both side columns before anchoring.
7
Anchor
the first side column to the wall at the
top of the column
and
baseplate
.
Set
anchors tight.
Remove
clamp.
Make sure
you have read
Before you begin
on page 9 before you start.
8
Measure and mark
the reference mark for the second side column.
KEEP
REUSE
c
a
b
5550300
2
13mm
Anchoring
hardware
Carpenter’s
square
Measuring
tape
Serial number
D0091893-010
Configuration
DOOR MODEL NAME
Spiral Full Vision "L"
Production Width in mm 3,660
Production Height in mm 3,260
Door head sizeB
Line Voltage 460V
motor mount side
Right Hand Motor
Motor Duty
Standard Duty Motor
Horsepower
2.0
Number of solid slats
0
Number of vent slats
0
Brake Release Location Release lever on side column
Hood style
No spiral hood type
Number of Springs 4
Spring Tension (in)
4.724
LH Inner Spring Pack Qty
0
LH Outer Spring Pack Qty
2
RH Outer Spring Pack Qty
2
0
Order type
ZP02
RYTEC MTO Order
Order number
20000597
MRP controller
500
B5 ZMAT
Creation Date
05/31/2019
Production scheduler
T7
Tier 7
Order quantity
1 EA
Finish
06/05/2019
Start
06/03/2019
Material number
724
Material description
SPIRAL STT-L
Reservation number
0002425475
Status
REL MSPT PRT PRC SETC
Object list
Original
Plant
2000
Rytec Corporation -
Door Width (Inches)
144.094
Door Height (Inches)
128.346
90 º
144 1/16
®
Use
the production
width from the object list.
Measure and mark
the reference line for
the other column.
9
Clamp the non-drive side column into place.
10
Anchor
the second side column to the wall, but
DO NOT SET ANCHORS TIGHT
until after
the head assembly is installed.
Make sure
you have read
Before you begin
on page 9.
11
Set
a laser line parallel to the wall 1” (one inch) in front of columns.
Make sure
the line is parallel to the wall.
Bar clamp
Align
base
plate against
reference mark.
Set clamp
inside
guide track above
light curtain.
On taller doors,
set a second
clamp.
Anchoring
hardware
Measuring
tape
Laser level
Measure
the distance
from the wall to the
laser line at
multiple locations.
Adjust
angle of
laser level until all
measurements
match.