Spiral
®
SST and STT Prewire Installation Manual
Spiral
®
SST and STT Prewire Installation Manual
■
1072124-0
■
Rev 03
■
01/22
22
(Optional) How to install BTA4 user terminal in a remote location
1
Locate
the BTA4 kit and
cable in the small parts box.
2
If you are mounting the unit to the wall and
cannot run cable inside the wall,
snap off
the
perforated tab at the bottom of the frame.
3
Install
the BTA4 frame using the supplied
hardware or your own.
4
Plug
the female quick connector on the cable into the
back of the BTA4 unit.
b
a
c
d
ID Part No.
Description
Qty.
a
1210765-0
BTA4 unit
1
b
1210766-0
BTA4 frame
1
c
5550351-0A01 Mounting hardware,
5
5550057-0Z01 side column
d
1210756-0
Mounting hardware,
5
5550353-0 wall
SMALL PARTS
1210800
#2
5
Line up
the two bottom tabs
on the BTA4 unit with the
bottom tabs in the frame
a
.
Then
snap
the two top
tabs into place
b
.
6
In the head assembly, on the drive side,
remove
the jumper from port 1 on the CAN repeater
a
and
plug in
the cable from the BTA4 terminal
b
.
▪
This port requires the least amount of cable routing to connect the remote BTA4 to the CAN bus.
The BTA4 user terminal will
automatically sync with the controller
when you manually sync the light curtains.
See
How to sync the SmartSurround™ system to the controller, set limits, and test the door
beginning on page 28.
a
b
a
b