5
Production Width Line
(Side Column Must Be
Located on Outside
Edge of Line)
Left Side Column
Anchor Holes
(Two Anchors
Required)
This Dimension
Must Be Equal on
Both Sides of Door
Opening
INSTALLATION—SIDE COLUMNS
Motor Mount Side
Column Has Wire
Access Hole
Water Level
A0500004
SIDE COLUMNS
Figure 11
Shim Plate
(If Required)
A7700020
Figure 12
NOTE: The standard mounting location for the
motor/gearbox assembly on a PredaDoor
NXT door is on the left but can be ordered
to be mounted on the right. DO NOT
change the location of the drive motor
without first contacting your Rytec
representative or the Rytec Technical
Support Department at 800-628-1909.
The PredaDoor NXT has only one access
hole in each side column.
1. Remove the drive motor side column from the ship-
ping crate. The drive motor side column is identified
by the wire access hole along its outside edge.
(See Figure 12.)
2. Stand the drive motor side column on the floor and
tight against the wall. To determine on which side of
the door to place the side column, be sure that the
access holes are facing away from the door opening.
3. Align the inside edge of the side column with the
production width line laid out earlier on the floor.
The side column must be located on the outside
edge of the layout line. (See Figure 13.)
Anchor Holes
(Three Anchors
Required)
Anchor Hole for
Door Opening
Over 9 ft. 6 in.
A7700021
Figure 13