Page 2
Victrix 24kW X Instructions
Introduction
Boiler Operating Instructions
The Victrix 24kW X boiler is a condensing wall hung, room sealed boiler. This boiler has the highest efficiency
possible for a gas boiler, ie 4 stars (****) in conformity with European Directive 92/42 EEC.
The boiler provides central heating and may also provide priority heating of the domestic hot water supply if
the optional 3 way valve kit is used (RVR Stock No: ACB515). It is designed for use with a fully pumped,
sealed and pressurised heating system using Natural Gas or LPG. The boiler is supplied for use with one of
these gas types and must be converted before it can be used on another gas. A boiler equipped for natural
gas must not be used on LPG or vice versa.
The boiler is supplied with a pump, automatic bypass, pressure relief valve, expansion vessel and pressure
gauge fully assembled and tested.
As supplied, the boiler will automatically modulate to provide central heating outputs between 4.7 and
26 kW .
IMPORTANT
All gas appliances must be installed by a competent and qualified person, in accordance with relevant clauses
of applicable standards and recommendations. These include but may not be limited to the following:-
I.S. 813 Domestic Gas Installations
I.S, 820 Non-Domestic Gas Installations
All relevant Building Regulations.
Local Water Bye Laws
IEE Wiring Regulations
Health & Safety legislation
This appliance meets the requirements of IPX4D, ie degree of protection against moisture.
Failure to install this appliance correctly could lead to prosecution. It is in your own interest and that of safety
to ensure that the law is complied with. Manufacturer's instructions must
NOT
be taken in anyway as over-
riding statutory obligations.
1. Boiler status indicator display
2. Main Switch OFF-DHW - DHW/Central
heating
3. Domestic hot water temperature selector
4. Central Heating temperature selector
5. Pressure Guage
Using the Boiler
Before lighting, make sure that the system is full of water and that the pressure guage (5) indicates a pres-
sure of 1 - 1.2 bar.
-Open the gas valve on the gas supply to the boiler.
-Turn main selector (2) to Domestic Hot Water or Domestic Hot Water and Heating
N.B.
With the switch (2) set to the
Central Heating temperature selector
(4) is disabled, the domestic hot
water temperature is regulated by selector (3): the display shows the Summer symbol . With the selector
set to the
Central Heating temperature selector
(4) is used to regulate the temperature of radiators while
selector (3) continues to be used for domestic hot water; the display shows the Winter symbol
Turn the selectors clockwise to raise the temperature, anticlockwise to lower it. Boiler operation is now
automatic.