Page 16
Victrix 24kW X Instructions
Operation and Maintenance Instructions
Description
Symbol
Key to control panel display symbols
Figures to indicate temperature, any error codes or optional
external temperature sensor correlation factor
Degrees symbol
External sensor connection symbol (Optional)
Symbol of connection to Remote Fiend Control device (Optional)
Summer symbol (domestic hot water production only)
Winter symbol (domestic hot water production and room heating)
Domestic hot water production
Room heating phase on symbol
Flue cleaning function symbol
Malfunction symbol (combined with error code)
Flame present symbol
Burner output scale symbol
Fault and anomaly signalling
.
The Victrix 24 kW boiler indicates any malfunctions using a code shown on the boiler display
(1). In case of malfunction or anomaly the problem is indicated by flashing of the symbol
and light-up of the relative error code:
Anomaly signalled
Error Code
Ignition Fault
01
Safety thermostat block (over temperature), ex-
haust thermostat or flame control anomaly
02
Delivery sensor anomaly
05
Domestic sensor anomaly
06
Reset selector broken
08
Calibration function on (displayed on RFC)
09
System pressure too low
10
Fan anomaly
16
Insufficient circulation
27
Remote control communication loss
31