Protection from electric shock
Shut down power to the fixture before carrying out any
installation or maintenance work.
Disconnect the fixture from AC power before removing or
installing any cover or part and when not in use.
Ensure that the fixture is electrically connected to ground
(earth).
Use only a source of AC power that complies with local building
and electrical codes and has both overload and ground-fault
(earth-fault) protection.
Replace defective fuses with ones of the specified type and
rating only.
Before using the fixture, check that all power distribution
equipment and cables are in perfect condition and rated for the
current requirements of all connected devices.
Isolate the fixture from power immediately if the power plug or
any seal, cover, cable, or other component is damaged,
defective, deformed, wet or showing signs of overheating. Do
not reapply power until repairs have been completed
Do not expose the fixture to rain or moisture.
Protection from burns and fire
Do not operate the fixture if the ambient temperature (T
a
)
exceeds 40° C (104° F).
Do not illuminate surfaces within 12 m (40 ft.) of the fixture. The
surface of the product casing can reach up to 85° C (185° F)
during operation. Avoid contact by persons and materials. Allow
the fixture to cool for at least 10 minutes before handling.
Keep flammable materials well away from the fixture. Keep all
combustible materials (e.g. fabric, wood, paper) at least 100 mm
(4 in.) away from the fixture head.
Ensure that there is free and unobstructed airflow around the
fixture. Provide a minimum clearance of 100 mm (4 in.) around
fans and air vents.
Do not attempt to bypass thermostatic switches or fuses.