Physical installation
The fixture is designed for indoor use only and must be used in a dry location
with adequate ventilation. Always ensure that none of the fixture’s ventilation
slots are blocked and always ensure that the product is firmly affixed to avoid
vibration during operation.
Fastening the fixture to a flat surface
The fixture can be fastened to a hard fixed flat surface that is oriented at any
angle. Ensure that the surface can support at least 10 times the weight of all
fixtures and equipment to be installed on it.
Fasten the fixture securely. Do not stand it on a surface or leave it where it can
be moved or fall over. Attach a securely anchored safety cable to the fixture if it
is installed in any location where it may fall and cause injury or damage if the
primary attachment fails.
Mounting the fixture on a truss
The fixture can be clamped to a truss or similar rigging structure in any
orientation. When clamping a fixture to a truss:
1. Check that the rigging structure can support at least 10 times the weight of
all fixtures and equipment to be installed on it.
2. Block access under the work area.
3. The fixture is supplied with two brackets to which clamps can be attached.
Attach these brackets to the base of the fixture and secure using the
quarter-turn screws.
4. Rig the fixture using clamps and hardware suitable for the purpose, such
as omega clamps. Working from a stable platform, hang the fixture on the
truss. Tighten the rigging clamps and hardware.
5. Secure the fixture against clamp failure with a secondary attachment such
as an approved safety cable that is rated for the weight of the fixture.
6. Check that the head will not collide with other fixtures or objects.