MH 3 Beam user manual
37
Error messages
Error:
Appears when:
Lamp Startup Fail
No lamp or some wires are damaged.
Temperature Sense Error
Temperature sensor on the PCB is damaged.
Lamp Too Hot Power Off
Temperature is detected higher than 110° C.
Ensure that the fixture is adequately ventilated.
The fans or temperature sensor might be
damaged (contact Martin support).
Lamp Too Hot Low Power
Temperature is detected higher than 105º C.
The fixture runs at a low power level.
Maintenance Fixture
Fixture maintenance is required (based on the
countdown timer). Maintain the fixture, and
then reset the countdown timer using the
menus.
Lamp On Over 700 Hour
The fixture has been on for more than 700
hours. Turn the fixture off.
Memory Initial Fail
Damaged memory IC (contact Martin support).
CPU-B Error, CPU-C Error,
CPU-D Error
Board P.C or fixture wiring is damaged
(contact Martin support).
Pan Reset Error
Pan Encode Error
Tilt Reset Error
Tilt Encode Error
Shutter Reset Fail
Dimmer Reset Fail
Color Reset Fail
Gobo Reset Fail
Frost Reset Fail
These can appear when powering on or
resetting the fixture and can indicate damage
to sensors or components (contact Martin
support).