RUSH DC1 Aqua User Manual
25
To clean the fixture:
1. Disconnect the fixture from power and allow it to cool for at least 10
minutes.
2. Vacuum or gently blow away dust and loose particles from the outside of
the fixture with low-pressure compressed air.
3. Clean the surfaces by wiping gently with a soft, clean lint-free cloth
moistened with a weak detergent solution. Do not rub glass surfaces hard:
lift particles off with a soft repeated press. Dry with a soft, clean, lint-free
cloth or low-pressure compressed air. Remove stuck particles with an
unscented tissue or cotton swab moistened with glass cleaner or distilled
water.
4. Check that the fixture is dry before reapplying power.
Replacing the primary fuse
If the fixture is completely dead, the fixture’s primary fuse F1 may have blown
and it may be necessary to install a new fuse. This fuse is located in a
fuseholder next to the MAINS OUT socket on the connections panel. See
‘Fixture overview’ on page 15.
If you need to replace a fuse:
1. Disconnect the fixture from power and allow it to cool for at least 10
minutes.
2. Unscrew the cap of the fuseholder and remove the fuse. Replace with a
fuse of the same size and rating only.
3. Reinstall the fuseholder cap before reapplying power.