RUSH DC1 Aqua User Manual
13
AC power
Read ‘Safety information’ on page 5 before connecting the
fixture to AC mains power.
Warning! The mains power input cable supplied with the
fixture is rated 6 A and can supply only one fixture with
mains power. Do not connect any device to the fixture’s
MAINS OUT power throughput socket when using this input
cable. If you want to connect other fixtures to the MAINS
OUT socket, see ‘Linking fixtures to power in a chain’ on
page 14.
For protection from electric shock, the fixture must be grounded
(earthed). The power distribution circuit must be equipped with a
fuse or circuit breaker and ground-fault (earth-fault) protection.
Socket outlets or external power switches used to supply the
fixture with power must be located near the fixture and easily
accessible so that the fixture can easily be disconnected from
power.
Do not insert or remove live power connectors to apply or cut power, as this
may cause arcing at the terminals that will damage the connectors.
Do not use an external dimming system to supply power to the fixture, as this
may cause damage to the fixture that is not covered by the product warranty.
The fixture can be hard-wired to a building electrical installation if you want to
install it permanently, or a power plug (not supplied) that is suitable for the
local power outlets can be installed on the power cable.
If you install a power plug on the power cable, install a grounding type
(earthed) plug with integral cable grip that is rated minimum 250 V, 6 A. Follow
the plug manufacturer’s instructions and connect the wires in the power cable
as shown in this table:
Live or L
Neutral or N
Earth, Ground or
US system
Black
White
Green
EU system
Brown Blue Yellow/green
The fixture has an auto-ranging power supply that accepts AC mains power at
100V~240V, 50/60Hz. Do not apply AC mains power at any other voltage or
frequency to the fixture.