background image

 

RUSH DC1 Aqua User Manual 

6

Respect all locally applicable laws, codes and regulations when 
installing, operating or servicing the fixture. 

There are no user-serviceable parts inside the fixture. Do not 
open it. Refer any service or repair operation not described in 
this manual to an authorized Martin™ service technician. Do not 
try to carry out any such operation yourself, as doing so may 
present a health or safety risk. It may also cause damage or 
malfunction and it may void your product warranty. 

 

Install, operate and service RUSH by Martin™ products only as 
directed in their user manuals, or you may create a safety 
hazard or cause damage that is not covered by product 
warranties. 

Follow the safety precautions listed below and observe all 
warnings in this manual and printed on the product. Keep this 
user manual for future use.  

For the latest user documentation and other information for this 
and all Martin™ products, please visit the Martin website at 
http://www.martin.com 

 

Protection from electric shock   

Do not expose the fixture to rain or moisture. 

Disconnect the fixture from AC power before carrying out any 
installation or maintenance work and when the fixture is not in 
use. 

Ensure that the fixture is electrically connected to ground (earth). 

Use only a source of AC power that complies with local building 
and electrical codes and has both overload and ground-fault 
(earth-fault) protection. 

Socket outlets or external power switches used to supply the 
fixture with power must be located near the fixture and easily 
accessible so that the fixture can easily be disconnected from 
power. 

Replace defective fuses with ones of the specified type and 
rating only. 

Isolate the fixture from power immediately if the power plug or 
any seal, cover, cable, or other component is damaged,  

Summary of Contents for DC 1 Aqua

Page 1: ...RUSH DC 1 Aqua User Manual Professional Entertainment Technology...

Page 2: ...ability to use or reliance on the information contained in this manual The Martin logo the RUSH by Martin logo the RUSH by Martin name the Martin name and all other trademarks in this document pertain...

Page 3: ...ture overview 15 Control data link 17 Tips for reliable data transmission 17 Connecting the DMX data link 18 Fixture setup 18 Using the control menus 18 DMX addressing 18 Standalone operation 19 Backl...

Page 4: ...DMX protocol 26 Control menus 28 Troubleshooting 30 Specifications 31...

Page 5: ...not view the light output with optical instruments or any device that may concentrate the beam This lighting fixture is for professional use only it is not for household use The fixture must be insta...

Page 6: ...uct Keep this user manual for future use For the latest user documentation and other information for this and all Martin products please visit the Martin website at http www martin com Protection from...

Page 7: ...have an outer cable diameter of 6 15 mm 0 2 0 6 in and be temperature rated to suit the application In the USA and Canada the cable must be UL listed type SJT or equivalent In the EU the cable must b...

Page 8: ...ypass thermostatic switches or fuses Do not stick filters masks or other materials onto any optical component Protection from eye injury Do not stare directly into the light output Ensure that persons...

Page 9: ...f bearing a static suspended load that is ten times the weight of the fixture and all installed accessories Check that all external covers and rigging hardware are securely fastened Do not operate the...

Page 10: ...hment Before using the product 1 Read Safety information on page 5 before installing operating or servicing the fixture 2 Unpack and ensure that there is no transportation damage before using the fixt...

Page 11: ...ce that is oriented at any angle Ensure that the surface and all fasteners used can support at least 10 times the weight of all fixtures and equipment to be installed on it Fasten the fixture securely...

Page 12: ...securely 5 Secure the fixture with a safety cable as directed below Securing with a safety cable Secure the fixture with a safety cable or other secondary attachment that is approved for the weight of...

Page 13: ...power Do not insert or remove live power connectors to apply or cut power as this may cause arcing at the terminals that will damage the connectors Do not use an external dimming system to supply pow...

Page 14: ...es to power in a linked daisy chain MAINS OUT throughput socket to MAINS IN input socket Using 14 AWG or 1 5 mm2 cables from Martin you can link Maximum twelve 12 RUSH DC1 Aqua fixtures in total at 10...

Page 15: ...ster mode SLAVE On Slave mode 3 Buttons The four buttons on the control panel have the following functions MENU Activate menus or Return to the previous level of the menu structure or Hold to exit the...

Page 16: ...socket is provided to connect the fixture to AC mains power 6 Mains power throughput The white Neutrik PowerCon socket can be used to supply power to other fixtures only if you respect the safety pre...

Page 17: ...transmission Use shielded twisted pair cable designed for RS 485 devices standard microphone cable cannot transmit control data reliably over long runs 24 AWG cable is suitable for runs up to 300 mete...

Page 18: ...nus press the MENU button Navigate the menu structure using the MENU ENTER DOWN and UP buttons Select any required menu option using the ENTER button To return to a higher level in the menu structure...

Page 19: ...slave operation Fixtures in standalone mode can be linked in a chain and set to master slave operation where one master fixture running a standalone show controls the behavior of slave fixtures Two sl...

Page 20: ...a DMX signal to all fixtures Then after a few seconds shut down the DMX signal Backlight To turn the control panel display backlight on or off 1 Select BACK LIGHT menu and press ENTER to confirm The p...

Page 21: ...ours readout Fixture Hours 1 To display the fixture s operating hours counter 2 Select FIXTURE HOURS and press ENTER The display will show the number of hours the fixture has been in operation since m...

Page 22: ...direction and speed to give a moving water effect Adjusting the rotation of the two wheels gives control over the water movement effect in the projection Color control The DC 1 Aqua features a color...

Page 23: ...ntensity can be adjusted 0 100 Focus Water effect projections tend to look best when focus is slightly softened See illustration below To soften or sharpen the water effect projection adjust focus by...

Page 24: ...by the product warranty The cleaning of external optical lenses must be carried out periodically to optimize light output Cleaning schedules for lighting fixtures vary greatly depending on the operati...

Page 25: ...ve stuck particles with an unscented tissue or cotton swab moistened with glass cleaner or distilled water 4 Check that the fixture is dry before reapplying power Replacing the primary fuse If the fix...

Page 26: ...or 3 75 Color 3 Blue 76 99 Color 3 Color 4 100 Color 4 Yellow 101 124 Color 4 Color 5 125 Color 5 Pink 126 149 Color 5 Open 150 160 Open Stepped indexing 161 165 Color 1 166 170 Color 2 171 175 Color...

Page 27: ...e Function 3 Wave effect 1 0 9 Blackout 10 120 CW rotation fast slow 121 134 Stop 135 245 CCW rotation slow fast 246 255 Stop 4 Wave effect 2 0 9 Blackout 10 120 CW rotation fast slow 121 134 Stop 135...

Page 28: ...as slave variation 2 Back Light Off LED display off when not in use On LED display on all the time Manual Mode Color 000 255 Manual color control 000 127 select color 128 186 color wheel CW rotation...

Page 29: ...RUSH DC1 Aqua User Manual 29 Menu Option setting Explanation Fixture Hours Total fixture operating hours counter Software Version Currently installed software version Reset Reset fixture...

Page 30: ...connector or cable or interference from proximity to a high voltage installation Ensure that fixture s DMX address matches address set on DMX control device Check that fixture s DMX indicator LED is...

Page 31: ...e direction and speed Electronic dimming 0 100 Focus Manual Control and Programming Control options DMX standalone master slave DMX channels 4 Setting and addressing Control panel with LCD display DMX...

Page 32: ...230 V 50 Hz 100 W 0 45 A Measurements made at nominal voltage at full intensity Allow for a deviation of 10 Thermal Maximum ambient temperature Ta max 40 C 104 F Minimum ambient temperature Ta min 0 C...

Page 33: ...rCon NAC3FCB output connector cable mount light grey P N 05342805 Related Items RUSH Software Uploader 1 P N 91611399 Ordering Information RUSH DC 1 Aqua in cardboard box EU model P N 90480050 RUSH DC...

Page 34: ...ayed on this product If it becomes difficult or impossible to read it must be replaced using the illustration below to reproduce a new label sized 45 x 18 mm in black on a yellow background RISK GROUP...

Page 35: ......

Page 36: ...I n n o v a t i o n Q u a l i t y P e r f o r m a n c e...