A serial link of RS232 or RS422 enables ASCII communication with the projector so that it
can be controlled remotely from a PC or other controller. From a PC, connect a standard
9-wire RS232 serial cable to the
RS232 IN
port. Or, for long-distance (>100 ft.) links with
an RS422-compatible PC or controller, connect RS422 cable to the
RS422
port.
Serial Communications Cables
APPENDIX B
From projector to DHD Controller (RS232)
From projector to Automation System
Automation
System
1 Gnd
2 Rx
3 Tx
4 Gnd
1 Gnd
2 Rx
3 Tx
4 Gnd
From projector to RS422 compatible control system
▪ Wiring from your control system (or RS232-to-
RS422 adapter) may vary. Consult the
documentation for your device.
▪ Connect Tx+ to Rx+
▪ Connect Tx- to Rx-
▪ Connect Rx+ to Tx+
▪ Connect Rx- to Tx-