73
Section 3: Operation
Section 3: Operation
Code
Description
GENERAL
12
Software bug. Contact dealer/factory.
13
CRC error in flash ROM. Download new software.
14
Engineering-only programming is complete. Call Runco, replace TIPM.
15
Attempting to download code without being in boot mode
16
Invalid interrupt. Power off/on. If it persists, contact dealer/factory.
17
User forced system to stay in boot mode
18
Jumper for programming boot not installed
LAMP FAILURES
20
Lamp turned on unexpectedly (fault related to ballast)
21
Lamp airflow low, overheating imminent
23
Cannot read valid ballast ID
26
Lamp 1 Interlock: lamp door open, lamp not installed
27
Can’t turn lamp on
28
Lamp turned off unexpectedly
29
Lamp ballast overheated
POWER AND COOLING
46
Red DMD temperature probe overheated
4C
Projector shutdown due to critical error
C0
Lamp blower failure (lamp not turned on)
51
LVPS fan failed (Fan 1)
52
LVPS/ Red cooling fan failed (Fan 2)
53
DC lamp fan failed in 500W / 1kW models (Fan 3)
54
Red DMD heatsink fan failed on 1kW and 1.2kW models (Fan 4)
55
Green DMD heatsink fan failed on 1kW and 1.2kW models (Fan 5)
56
Blue DMD heatsink fan failed on 1kW and 1.2kW models (Fan 6)
57
TIPM fan failed (Fan 7)
58
TIPM fan failed (Fan 8)
TIPM (Image Processor)
60
Boot code CRC failed
61
Unable to program DigMux PLD
62
Unable to program Control PLD
63
Unable to program Bubks PLD
64
Unrecognized ROM type
65
Write to flash ROM failed
66
TIPM failure
67
Downloaded code will not fit
68
Scaler communication problem
BUILT-IN KEYPAD
70
Unable to access EEPROM on the built-in keypad
71
EEPROM memory re-initialization on the built-in keypad
PANEL DRIVER AND FORMATTER
80
Unrecognized Panel Driver
81
Unable to program device on Panel Driver
82
TI flash download failure
83
TI flash download failure
84
TI flash download failure
85
TI-I2C write failure
86
One or more Formatters not responding — Probable Formatter s/w fault
87
Formatter reports RDRAM failure
88
Red modular Formatter communication failure
89
Green modular Formatter communication failure
8A
Blue modular Formatter communication failure
93
Modular formatter architecture error
94
Modular formatter DMD mismatch
95
Modular formatter sequence mismatch
MISCELLANEOUS
A0
Unable to program the optional module
A1
Unable to power the optional module
A2
Unable to program the Dual Slot Backplane Module (DSBP)
A3
Unable to program the optional Post Processing Module (Warp module)
Clear system errors with ‘Exit Exit’. If
necessary, try resetting the projector
by powering it off and on again (cooling
if necessary). Contact dealer/factory
if error persists. Codes omitted from
this table should not appear in your
projector.
Table 3.5 Error Codes