KT332N Cutting &engraving control system user manual V1.1
11
assigned as second pen control. the multiplexing function is
also enabled by auxiliary air control is enabled or not.
Output is an open collector type. When working, this output
connect to GND.
4
Out1
General output, reserved.
5
Out2
General output, reserved.
6
GND
Signal Gnd
Prompt
All output signals are isolated by opto-couplers. OC output, the
maximum driving capacity is 300mA, which can directly drive 6V / 24V
relay.
4.6 General/ dedicated input interface INPUT
PIN
SIGNAL
Definition
1
GND
Power ground (output)
2
IN1
General input, reserved
3
IN2
General input, for a remote laser shot control. When
connected to GND, it can perform laser pulse.
4
IntLock
Dedicated input, protection signal input. If the machine needs
to be protected in a specific state (such as cover open), the
alarm signal is input to this port. This port can be enabled
and disabled. When this port is disabled, this signal is
neglected by the controller. If this port is enabled, the
machine is protected when the input is in high voltage or the
port is float. Once the alarm triggered, motion will be stopped
and the laser is switched off synchronously.
5
Ex-Run
Dedicated input. Extern start input. Usually for foot control
switch start the machine. Low level is valid.
When system is idle, if a low level signal is sent to this port,
machine will be start. If the machine is working, a low level
signal is sent to this port, machine will be stopped. Send
again, machine will go on working.
6
+24V
Power 24V (output)
4.7 Limit input
X/Y axis limit interface CN4
PIN
SIGNAL
Definition
1
+5V
Power ground (output)
2
LmtU+
U+
,
U axis moves to the limit at the maximum coordinate