RDLC320 Controller User Manual
36 / 45
© 2016 Ruida Technology. All Rights Reserved.
Maximum Power 1
Minimum Power 1
Laser PWM Frequency 1
Maximum Power 2
Minimum Power 2
Laser PWM Frequency 2
Laser Attenuation Quotiety
Laser PWM Frequency is to set the pulse frequency of control signal used by the laser, in general,
glass tube is about 20KHZ, RF laser is about 5KHZ; the maximum/minimum power (%) is used to
set the limit power of the laser tube, that is to say, when running, the maximum power of user
setting can’t be higher than the maximum power and the minimum power of user setting is no less
than the minimum power. When the laser power is attenuated after using for a time, user can set
the laser power by the attenuation quotiety; if no attenuation, the quotiety is 0.
If it is only provided with the single laser, it will show the one-path parameter.
(3) Other Manufacturer Parameters
Machine Type
: In most cases, the “normal” engraving machine should be selected and other types
are used for specific machines.
Feed Mode
: single-direction mode and bi-direction mode for optional. If it is single-direction
feeding, it is unnecessary to check the coordinates, feeding can be conducted in the
single-direction mode; if it is bi-direction feeding, the system will check the maximum and
minimum coordinates. The odd sequence means feeding should be done to one direction and the
even sequence means feeding done to the other direction. The initial direction for the first time can
be changed through setting the directional polarity or modifying the positive and negative values
of the feeding length. This parameter is valid only when the “Z function” is configured to “Drive
for Feeding axes”.
Power-Off-Restart Delay
: it can be set 0~3000ms. After power-off, the system power supply will
be not dropped to 0V at once. There is a delay during the time. The delay value should be set
basically the same as the actual power off delay value. If the deviation is larger, when in
continuous engraving power-off-restart, the processing graphics is either not close with before, or
coincided too much.
Transmission Mode
: generally choose “Belt + step motor”, the control algorithm will be changed
a little when other types are selected.
Z-axis Function
: “platform” and “feeding axis” are optional.
Prompt