6.3)
Manual Control Inputs
.
Pin
Name
Function
Output Controlled when ‘Manual as
Remote’ disabled
BANK A Name Pin
1
Manual 4
Input
Channel 1
1
2
Manual 3
Input
Channel 2
4
3
Manual 2
Input
Channel 3
7
4
Manual 1
Input
Channel 4
10
5
Manual 5
Input
Channel 5
3
6
Manual 6
Input
Channel 6
6
7
Manual 7
Input
Channel 7
9
8
Manual 8
Input
Channel 8
12
9
N/C
10
Ground
BANK B Name Pin
11
Manual 9
Input
Channel 9
1
12
Manual 10
Input
Channel A
4
13
Manual 11
Input
Channel B
7
14
Manual 12
Input
Channel C
10
15
Manual 13
Input
Channel D
3
16
Manual 14
Input
Channel E
6
17
Manual 15
Input
Channel F
9
18
Manual 16
Input
Channel G
12
All Inputs are Active High (+12V). When “Use Manual Inputs as Handheld” option is selected, these
inputs act the same as handheld buttons. When this option is not selected, the inputs directly control the
associated output. i.e. if input 1 is on, output 1 will be activated.