3.6)
RS485 Serial Interface
.
The CVS012 currently supports the MHE Handheld Controller, and the Generic Handheld
Controller (S-Link Protocol)
3.7)
CAN Bus Serial Interface.
A CAN Bus interface has been provided for communication with vehicle management systems and
for the CVS012 Expansion Module.
Please Note: Currently only Ford Focus is supported.
When CAN Bus Option 1 (Ford Focus) is selected (and connected) the Vehicle Speed will be transmitted as a square
wave frequency from Pin 5 (Can Data Monitor 1) of the Power Bank A Connector
3.8)
AND Logic
Overview
The AND Logic system is designed to inhibit specific outputs when a control signal is present.
Output channels 4, G and manual input 16 have been selected for use with the AND Logic system.
Functional Description
If enabled, when a high signal is present at manual input 16, outputs 4 and G will be inhibited
(turned off).
It is possible to reverse this feature and inhibit the outputs when the high signal is removed by
setting
AND Inversion
to “ON”
4) User Interface
The user interface consists of a graphic display, and 4 buttons for navigation and making
changes to menu option.
4.1)
Display Contrast Settings
To adjust the contrast on the display: Press and hold the Enter Button, and use the ‘up’ and
‘down’ buttons to adjust the contrast level. This level is stored permanently in memory.