MEASUREMENT
13/10/2016 Version No. 001
77
1. Select PWM
setting
From one of the main screens, press the
ESC
key so that the menu system at
the bottom of the display has focus.
Go to Meas. Setup and press Enter.
Go to PWM and press Enter.
Meas. Setup
menu icon
Move
Select menu
or setting
Enter
2. PWM setting
appears
Use the arrow keys to set the ON and OFF time for the duty.
Press Enter to confirm the setting.
PWM
Line Frequency
Auto, 50Hz, 60Hz
ON
OFF
03 ~ 99 time units*
0100 ~ 9999 ms
*The ON time setting is set in “time units”, not milliseconds. The
amount of time in a time unit depends on the line frequency
settings
Line frequency
1 Time Unit
60Hz
16.6mS
50Hz
20mS
Note
Pressing ESC before pressing ENTER will exit the PWM settings.