background image

HygroPalm

HygroPalm

HygroPalm

HygroPalm HP23

HP23

HP23

HP23 Hand-Held

Hand-Held

Hand-Held

Hand-Held Indicator

Indicator

Indicator

Indicator

User

User

User

User Guide

Guide

Guide

Guide

HP23

HP23

HP23

HP23

手持表使用手册

Summary of Contents for HygroPalm HP23

Page 1: ...Palm HygroPalm HygroPalm HygroPalm HP23 HP23 HP23 HP23 Hand Held Hand Held Hand Held Hand Held Indicator Indicator Indicator Indicator User User User User Guide Guide Guide Guide HP23 HP23 HP23 HP23 手持表使用手册 ...

Page 2: ...s 显示和显示模式 10 4 2 Keypad键盘 11 4 3 Internal menu 内部菜单 12 4 4 Frequently used settings常用设置 15 4 4 1 Unit system单位制 15 4 4 2 Date and time 日期和时间 15 4 4 3 Select the calculated parameter for a probe input如何选择探头输入的计算参数 15 4 4 4 Select which probe and or parameters are shown on the display如何选择显示探头信息以 及参数选择 15 4 4 5 Set input 1 or 2 for a digital or analog probe 设置一通道或二通道作为数字或模拟探头输 入 16 4 5 Practical advi...

Page 3: ...lity Applicability Applicability 应用 This manual is valid for the HP23 with firmware version 1 x where 1 x can be 1 0 1 1 etc Changes to the last digit of the version number reflect minor firmware changes that do not affect the manner in which the instrument should be operated 该手册适用于HP23系列所有产品固件版本为1 x 1 x可以是1 0 1 1 等 版本号最后位的变化 不影响 设备的使用 1 1 1 1 Overview Overview Overview Overview 概述 The HP23 is a m...

Page 4: ...digital or analog 两个探头的测量值的区别 两个探头必须是相同类型 均为数字探头或均为模拟探头 o Any parameter measured by up to two analog probes user defined 任何测量的参数取决于两只模拟探头 根据用户设定 v Manual Manual Manual Manual Data Data Data Data Capture Capture Capture Capture 手动数据捕捉功能 o To facilitate the spot checking of humidity and temperature conditions the HP23 features eight data bins non volatile memory each capable of retaining up to 250 h...

Page 5: ...nment HP23可以做单点或多点的湿度调节同时也可以做单点或2点温度调节 对比已知参考环境 Aw Aw Aw Aw Mode Mode Mode Mode this specialized mode is available only with model HP23 AW and is meant to be used exclusively with the HygroClip 2 digital probes and is used for measuring the water activity Aw of product samples and materials in bulk such as powders seeds etc When set to operate in the water activity mode the HP23 automatically disp...

Page 6: ...ly update both the HP23 and HygroClip 2 probe firmware means that the indicator and probes can be kept up to date regarding any future functionality improvement 用户具有易于更新 HP23 和 HygroClip 2 探头的固件能力 是指手持表和探头与任何未来功能提升保持同 步 2 2 2 2 General General General General description description description description 综述 2 1 2 1 2 1 2 1 Configuration Configuration Configuration Configuration software software...

Page 7: ... 典型电流消耗如下 使用1个探头6 5mA 1个探头 背景光显示需要消耗20 mA WARNING WARNING WARNING WARNING the display refresh rate setting can affect the data logging function of both the HP23 and probe 警告 显示刷新率的设置对HP23及探头的数据记录功能有影响 2 3 2 3 2 3 2 3 Probe Probe Probe Probe inputs inputs inputs inputs探头输入接口 The HP23 has two probe inputs Using the HW4 software Device Manager each probe input can be configured to accept one of the f...

Page 8: ...ity and temperature The HC2 probes measure relative humidity with a ROTRONIC Hygromer IN1 capacitive sensor and temperature with a Pt100 RTD HygroClip 2探头 湿度和温度 HC2探头通过ROTRONIC Hygromer IN1电容传感器测相对湿度 通过 Pt100 RTD测温度 o Analog probe general any parameter measured by the probe The parameter unit must be specified with the HW4 software Device Manager 模拟探头 常用 探头的任何参数 参数的单位必须通过HW4软件 设备管理器 进行设置 o Analog ...

Page 9: ... on on the the the the display display display display液晶显示报警 Depending on the type of alarm the display shows either a symbol or a text when the HP23 detects an alarm condition 当HP23监测报警时 根据不同的报警方式 液晶显示符号或文本 o Out of limits value defined with the HW4 software for each probe input includes measured values and calculated parameter 输出极限值时报警 通过HW4软件对每个探头输入做定义 包括测量值和计算参数值 o No communication with the pr...

Page 10: ...We have provided below a short description of the HP23 functions and also indicated the factory default settings HP23 可以只作为温湿度显示仪表 对HP23的功能设置 完全取决于用户 恰当的设置也依赖于用户应用 我们提供HP23的以下简短的功能描述 并做出厂默认设置进行说明 3 1 3 1 3 1 3 1 Factory Factory Factory Factory default default default default settings settings settings settings 工厂默认设置 Notes Notes Notes Notes 说明 o Configuration of the HP23 and probe by the user and ...

Page 11: ... K No calculation 无 Display backlight 背景光显示 K On Key Press 按键显示 Displayed parameters display mode 参数显示 显示模式 K RH and temperature date and time RH和温度 日期和时间 Display resolution 结果显示 K 1 decimal 1为小数 Trend indicator display 趋势指示 带显示 K Enabled 激活 Menu access from keypad 通过按键进入菜单选项 Enabled 激活 Delta Probe difference Pbe1 Pbe 2 第三方探头 不同于探头1和探头2 K Disabled 未激活 HP23 HP23 HP23 HP23 Functions Functions Functi...

Page 12: ...W4v2 A2 001 E M AC3000 CP E M AC3000 CP E M AC3000 CP E M AC3000 CP 3 2 3 2 3 2 3 2 Interaction Interaction Interaction Interaction between between between between the the the the HP23 HP23 HP23 HP23 and and and and HygroClip HygroClip HygroClip HygroClip 2 2 2 2 probe probe probe probe functions functions functions functions HP23 HP23 HP23 HP23与HC2 HC2 HC2 HC2探头的内部动作说明 It is important to note tha...

Page 13: ...s of the display refresh interval LCD的刷新间隔 当该设置超过1秒 引起HC2探头在显示更 新时断电 说明 当HP23正在记录数据过程中 探头在记录间隔时供电 与显示屏刷新间隔无关 Simulator function 模拟器功能 X X Generates fixed humidity and or temperature value When enabled the HP23 settings override the HC2 probe settings 生成固定湿度和 或温度值 当该功能被激活 HP23设置覆盖 HC2探头设置 Unit system 单位制 X X The HP23 setting overrides HC2 probe setting The HC2 probe settings still apply when the pr...

Page 14: ...Large Large Large 大屏显示 o o o o RH RH RH RH o o o o RH RH RH RH Both Both Both Both the the the the parameter parameter parameter parameter o o o o Temperature Temperature Temperature Temperature o o o o Temperature Temperature Temperature Temperature and and and and probe probe probe probe can can can can be be be be o o o o Date Date Date Date and and and and time time time time o o o o Calculate...

Page 15: ... change a value 当该菜单激活 用于移动菜单项 做选择或更改数值 ENTER ENTER ENTER ENTER 确认键 o When the menu is active use to confirm the selection of a menu item effect a change of settings and confirm any change 当该键激活 用于确认菜单项的选择 更改设置变化 o In the HP23 Standard Mode use to capture the current RH and temperature data to one of 8 data bins 在HP23的标准模式下 用于获取8位的当前 RH和温度数据 o In the HP23 AW Mode use to start hold or stop the wate...

Page 16: ...Device Device Info Info Info Info设 备信息 Serial Nbr 序列号 Serial number 序列号 Version 版 本 Firmware version 固件版 本 Type 类型 Device type 设 备类型 Name 名称 Device name 设备名称 User defined Battery 电池 Battery charge status 电池充 电状态 Device Device Device Device Settings Settings Settings Settings 设备设置 Display Settings 显示设置 Trend 趋势 ON OFF 开 关 Trend indication on the display 液晶显示趋势指示 Decimals 小数 1 or 2 Display resolutio...

Page 17: ...入 2 See Input 1 See Input 1 Main Main Main Main Menu Menu Menu Menu 主菜单 Menu Menu Menu Menu Items Items Items Items菜 单选项 Submenu Submenu Submenu Submenu Items Items Items Items 子 菜单 Selections Selections Selections Selections or or or or Information Information Information Information选择 信息 Notes Notes Notes Notes 说明 Pressure 压力 Fixed barometric pressure value used as an input for some psychrometri...

Page 18: ...own reference environment 手 动进入 已知参考 环境 Saves value entered manually as a cal Point 保存手动键入的值作为一个校准点 Adjust Adjusts the probe 调节探头 Effect depends on number of calibration points in probe memory 取决于探头存储器 内保存的校准点的数量 Reset to Factory 恢复出厂 设置 Returns the probe to the initial factory adjustment 恢复探头最初出厂调整值 Temp Adjust Acquired Points Lists the cal points present in the probe memory a max of 2 points are...

Page 19: ... Selections Selections Selections Selections or or or or Information Information Information Information 选项或信息 Notes Notes Notes Notes说明 Data Data Data Data Capture Capture Capture Capture 数据捕捉 o Displays the names of the 8 data bins显示8个数据位的名称 o Press on ENTER to select the highlighted data bin 按ENTER键选择日期位为高亮状态 View Data 数据浏览 o Shows the individual data records 显示独立的数据记录 o Use the up and down key...

Page 20: ...artStop Loop Start Stop the recording stops when the memory is full 启动停止模式 当存储器满 记录停止 Loop when the memory is full the oldest record is dumped to make room for the new record 循环模式 当存储器满 老的数据会腾 出空间给新的记录数据 Probe 1 ON OFF Probe2 ON OFF Aw Aw Aw Aw Mode Mode Mode Mode Enable激 活 ON OFF Enable ON changes the display as follows 激活 通过显示屏做如下更 改 o Humidity unit changes to aw 湿度单 位更改为AW o No calculated param...

Page 21: ...t Unit Unit Unit system system system system 单位制 Press the MENU key and select Device Settings Local Settings Unit Sys Press ENTER to activate the Unit Sys menu item use the UP or DOWN arrow key to change the unit system Press ENTER to confirm and press MENU to exit 按MENU键并选择设备设置 本地设置 单位制 按ENTER键激活单位选项 使用UP或DOWN方向键更 改单位制 按ENTER键确认并按MENU菜单键退出设置 The HW4 software can also be used to change the unit s...

Page 22: ... on on the the the the display display display display 选择显示哪个探头和 或参数 Press the MENU key and select Device Settings Display Settings Mode Press ENTER to activate the Mode menu item use the UP or DOWN arrow key to select the display mode Press ENTER to confirm and press MENU to exit 按MENU键并选择 设备设置 显示设置 模式 按ENTER激活模式菜单选项 使用UP或DOWN方向键选 择显示模式 按ENTER 确认并按MENU键退出 Depending on the display mode use the UP ...

Page 23: ...calibration of the sensor However the sensor has to dry out before it can provide a valid measurement 在恶劣环境中 当探头比环境温度低时会在传感器上结露 只要温湿度值不超过湿度传感器的测量范围 凝露不会影响传感器的校准 尽管如此 为了得到有效测量结果应该在测量之前 擦干传感器 Non moving air is an excellent insulator When there is no air movement surprising differences in temperature and humidity can noted over short distances Air movement at the probe generally results in measuremen...

Page 24: ...t the data bin to be viewed Press ENTER to confirm and open the data bin sub menu Use the UP or DOWN arrow key to select a menu item and press ENTER to confirm 按MENU键并选择数据捕捉 按ENTER激活数据捕捉菜单项 使用UP或DOWN方向键选择数据位 以便 浏览 按ENTER 确认并打开数据位总菜单 使用UP或DOWN方向键选择菜单项并按ENTER确认 o View View View View Data Data Data Data view individual data records 浏览数据 浏览独立记录数据 o Summary Summary Summary Summary view the maximum mini...

Page 25: ...igure Configure Configure the the the the data data data data logging logging logging logging function function function function and and and and start start start start recording recording recording recording data data data data 设置数据记录功能并开始记 录数据 o Press the MENU key and select Data Logging Press ENTER to activate the Data Logging menu 按MENU键并选择 数据记录 按ENTER 激活数据记录菜单 o Use the UP or DOWN arrow key ...

Page 26: ...data data 浏览记录数据 Data recorded with the HP23 data logging function can be viewed only after connecting the HP23 to a PC with the HW4 software running For instructions see the following HW4 manual E M HW4v2 F2 012 E M HW4v2 F2 012 E M HW4v2 F2 012 E M HW4v2 F2 012 HP23 数据记录功能只有在 HP23 与运行 HW4 软件的 PC 连接时才能浏览 详细说明见 HW4 手册 E M HW4v2 F2 012 5 3 5 3 5 3 5 3 Calibrator Calibrator Calibrator Calibrator fun...

Page 27: ... display is frozen When temperature conditions are stable both at the product and probe the value measured with the AwQuick mode is generally within 0 005 aw of the value that would be obtained by waiting for full equilibration of the product and probe AwQuick AwQuick AwQuick AwQuick选项 HP23使用算法加速水活性的测量 并在典型5分钟内得出测量结果 测量过程 自动结束 并显示固定值 当温度环境稳定 产品和探头均温度平衡 使用AwQuick模式 当 探头和被测产品完全平衡时 测得的值 通常误差范围在 0 005...

Page 28: ...is less than the specified value Recommended value 0 0001 Aw min 当湿度信号变化率低于给定值时 HP23认为湿度平衡 推荐值 0 0001 Aw min 5 4 2 5 4 2 5 4 2 5 4 2 Using Using Using Using the the the the AwQuick AwQuick AwQuick AwQuick measurement measurement measurement measurement option option option option AwQuick AwQuick AwQuick AwQuick测量选项 The HP23 uses an algorithm to project the full equilibrium value water activity of ...

Page 29: ...e measurement starts simultaneously for both probes 两路探头同时开始测量 o Usually the measurement ends at a different time for each probe 通常情况下 每个探头的停止测量时间不同 o Each probe can be displayed by using the UP or the DOWN key 每个探头在线测量数值均可以通过按UP或DOWN键显示 o Do not press on ENTER until the measurement has ended for both probes 直到2路探头测量结束再按ENTER确认 o The HP23 can be used with one probe only HP23可以与单只探头配合使用 1 1 1 1 AWQ...

Page 30: ...Ended Ended Ended when the projection is stable for the probe being displayed the HP23 automatically ends the measurement and freezes the display for that probe When measuring with two probes use the UP or DOWN key to verify the status of the other probe Do not press ENTER until the measurement is ended for both probes AWQ AWQ AWQ AWQ Ended Ended Ended Ended 当目标稳定显示 HP23 自动结束测量并保持探头的显示 ...

Page 31: ...ing a few minutes the measurement is automatically ended Depending both on the product being measured and on the stability of temperature measurements typically require 30 to 60 minutes HP23监控水活性和温度值 当两个值通过几分钟后均达到平衡 测量自动结束 由于被测产品和温度稳定 时间的不同 测量时间要求30 60分钟 NOTES NOTES NOTES NOTES 说明 o The measurement starts simultaneously for both probes 两路探头同时开始测量 o Usually the measurement ends at a different time ...

Page 32: ...als for equilibrium HP23 监控温湿度信号平衡状态 3 3 3 3 AWE AWE AWE AWE Ended Ended Ended Ended when both the humidity and temperature signals of the displayed probe are stable the HP23 automatically ends the measurement and freezes the display for that probe When measuring with two probes use the UP or DOWN key to verify the status of the other probe Do not press ENTER until the measurement is ended for bot...

Page 33: ... the HP23 HP23 HP23 HP23 to to to to a a a a PC PC PC PC HP23 HP23 HP23 HP23与PC PC PC PC连接 Any USB cable mini USB connector at one end can be used to connect the HP23 to a USB port of a PC running the ROTRONIC HW4 software Prior to connecting the HP23 the ROTRONIC USB driver must be installed on the PC Both the driver and the installation instructions document E M HW4v2 Main E M HW4v2 Main E M HW4...

Page 34: ... 年 为了实现最大的精确度 需每隔 6 到 12 个月校准一次 应用在 暴露的有重大污染的环境下的探头 需要经常校准 6 5 6 5 6 5 6 5 Cleaning Cleaning Cleaning Cleaning or or or or replacing replacing replacing replacing the the the the probe probe probe probe dust dust dust dust filter filter filter filter 清理或更换探头防尘过滤器 See document E M HC2 Probes V1 见文件E M HC2 Probes V1 6 6 6 6 6 6 6 6 About About About About the the the the HP23 HP23 HP23 HP23 calibrat...

Page 35: ...de some ventilation that is common to both the reference probe and device to be adjusted 校准参考探头和设备 需要将其放置在相同的环境中 等待与环境完全平衡 在静止的空气环境里 强烈 推荐提供通风 因为那是调节参考探头和设备的共同的要求 o Press the MENU key and select either Probe 1 or Probe 2 The reference probe is assumed to be connected to the non selected input Press ENTER to activate the Probe 1 or Probe 2 menu item 按MENU键并选择 Probe 1 或 Probe 2 参考探头假定连接到HP23的其他设备未选定...

Page 36: ...enu item and press ENTER to confirm 按ENTER确认并打开子菜单 使用DOWN方向键选择 Acquire Ref Probe 并按ENTER确认 o Humi Adjust the HP23 displays both the current humidity read by the device to be calibrated and the reference humidity known environment Press ENTER to activate the reference value menu item and use the UP or DOWN arrow key to change each digit Press ENTER to move the cursor to the right When done press EN...

Page 37: ... humidity adjustment adjustment adjustment adjustment 使用DOWN方向键选择 Temp Adjust 或 Humi Adjust 我们推荐先做温度调节 温湿度调节以下步 骤相同 o Press ENTER to confirm and open the next sub menu 按ENTER确认并打开下级子菜单 o Optional with the Acquired Points menu item selected press ENTER and review the calibration points present in memory This submenu allows you to delete unwanted calibration points Press MENU when done 选项 选择 Acquire...

Page 38: ... 012 E M HW4v2 F2 012 E M HW4v2 F2 012 8 8 8 8 Technical Technical Technical Technical data data data data技术数据 8 1 8 1 8 1 8 1 Specifications Specifications Specifications Specifications 说明 General General General General 概述 HP23 HP23 HP23 HP23 Device type 设备类型 Humidity temperature hand held indicator with 2 configurable probe inputs HygroClip 2 or analog probe and real time clock date and time 2路...

Page 39: ... Calculated Calculated parameters parameters parameters parameters 计算量参 数 HP23 HP23 HP23 HP23 Psychrometric calculations 湿度计 算量参数 Dew point Dp above and below freezing 露点 Dp 以上和冰点 以下 Frost point Fp below freezing and dew point above freezing 霜点 Fp 低于冰点和露点高于冰点 Wet bulb temperature Tw 湿球温度 Tw Enthalpy H 焓值 H Vapor concentration Dv 水汽密度 Dv Specific humidity Q 水汽含量 Q Mixing ratio by weight R 混合比 R Vap...

Page 40: ...capacity per probe is cut in half when two probes are being simultaneously recorded o 可设置记录间隔 从5秒到1小时 o 启动 停止或循环模式 o 单只HygroClip 2探头 最多记录10 000组RH T 数据 o 单通道模拟探头最多记录20 000组数据 o 每个数据记录都有时间标记 Calibrator 校准 o Can be used to calibrate and adjust HygroClip probes transmitters and other devices based on the AirChip 3000 technology o Fully fledged calibration and adjustment function o Calibration against...

Page 41: ...r material 探头防尘过滤器材料 Polyethylene聚乙烯 Conformity Conformity Conformity Conformity with with with with standards standards standards standards 符合标准 HP2 HP2 HP2 HP23 3 3 3 CE EMC immunity 免检 EMC 执行 2004 108 EG EN 61000 6 1 2001 EN 61000 6 2 2005 EN 61000 6 3 2005 EN 61000 6 4 2001 A11 Solder type焊接方式 Lead free RoHS directive 无铅 RoHS要求的产品 FDA GAMP directives 执行 compatible 兼容 Environmental Environmenta...

Page 42: ... E M HC2 accessories E M HC2 accessories E M HC2 accessories Accessories and parts for probes indicators and transmitters 探头 手持表及变送器的附件和配件 E T AC3000 DF V1 E T AC3000 DF V1 E T AC3000 DF V1 E T AC3000 DF V1 AirChip 3000 Description and Main Functions AirChip 3000说明书及功能介绍 E M HW4v2 DIR E M HW4v2 DIR E M HW4v2 DIR E M HW4v2 DIR List of the HW4 manuals HW4手册 E M HW4v2 Main E M HW4v2 Main E M HW4v2 Ma...

Page 43: ... the ROTRONIC humidity standards 使用ROTRONIC湿度标准的温湿度校准基本说明 E T HumiDefs E T HumiDefs E T HumiDefs E T HumiDefs Humidity Definitions 湿度定义 Note All document file names have an extension corresponding to the document release number This extension is not shown in the above table 说明 所有文件名有一个扩展对应文件 Doc Doc Doc Doc Release Release Release Release 文件发行 Date Date Date Date 日期 Notes Notes Notes Notes说明 _20 J...

Reviews: