Application error
Error message:
Possible causes
Remedial action
For more detailed information regarding the alarms below, consult the alarmlist in the display.
10
Pwr output, Tiltrotator!
Error in output signal (open or short circuit)
at TCU.
Go to error list, press OK on the alarm to see
which function is defect.
Cable breakage or electric coil fault.
Check the harness in terms of crush damage or open
circuit.
Check valve electric coils connectors and wires.
Return the roller to the zero position.
Contact the service workshop.
11
External voltage, coupler!
External voltage detected on output to coupler
valve.
2=CCU 1=TCU
Check the harness in terms of crush damage or open
circuit.
Check valve electric coils connectors and wires.
Return the roller to the zero position.
Contact the service workshop.
12
Forced Double shunt!
Refer to Instruction of Use ICS
13
Uncalibrated Roller!
Roller not calibrated. The control system
clears the roller’s calibration and stops output
signals.
Connector play or roller fault.
Calibrate the roller by pulling it to each end position for
at least 3 seconds.
Change the roller and perform calibration as set out
above
Contact the service workshop.
14
Roller active at start!
Roller activated upon start-up of
control system.
The roller output signal and the output signal
to the proportional valve are locked by the
system.
Return the roller to its zero position.
Check that none of the rollers are mechanically blocked.
Check the condition of the rollers.
Restart the system.
Contact the service workshop.
15
Shut-off lever!
Shut-off-Lever in wrong position to operate. Open and close the basemachine’s Shut-off-Lever.
Check harness, connectors and base-machine lever
switch.
Contact service workshop.
17
Coupler function disabled!
Coupler error
Check specific error, repair and restart
18
Double shunt active!
No tiltrotator attached, system in double shunt mode. Refer to
Instructions of Use
19
Steering error!
Problem with joystick steering, check display
for specific error.
Go to Menu Troubleshoot, select alarm and confirm to
get detailed information.
Refer to Instruction of Use : ICS Direct
20
Steering Pressure!
Pressure too low in joystick steering
Adjust lower limit,
Refer to Installation Instructions ICS
Direct
21
Locking switch active!
Coupler switch engaged prior to display
initiation
Deactivate Coupler Switch and try again.
22
Equipment not coupled!
QuickChange not correct attached
If tool is attached:
Refer to Instruction of Use : ICS
23
Power output, AUX!
Error in output signal from expansion module. Check the harness in terms of crush damage or open
circuit.
Check valve electric coils connectors and wires.
Return the roller to the zero position.
Contact the service workshop.
24
PWM-out! Cabin c.2
Error PWM passthrough 2, Error Feedback
from PWM
Check the harness in terms of crush damage or open
circuit.
Check if PWM to analog module is OK
25
Power output, PWM-spare Error in output signal from PWM spare
Check the harness to the joystick in terms of crush
damage or open circuit.
Restart the system.
Contact the service workshop.
30
No pulses from rotation
sensor!
Pulses from Rotation sensor required but
missing.
Check if rotation function is OK
Check the sensor
Check the rotation indicator
31
Coupler sensor disabled
Error in coupler sensor acknowledged
Check the harness in terms of crush damage or open
circuit.
Check the sensor/ electrical swivel
Contact the service workshop.
© Rototilt Group AB
2018-08-10
Alarm:2
English
EN
EN -