© Rototilt Group AB
2018-08-10
schema:1
Schematics
Valveblock Swivel
1. Rotation Left, connection
2. Rotation Valve
3. Rotation Right, connection
4. Grapple/Extra Open, connection
5. Extra Valve
6. Grapple/Extra Close, connection
. Coupler 1, connection
7. Coupler Valve
². Coupler 2, connection
8. Extra 2 Left, connection
9. Extra 2 Valve
10. Extra 2 Right, connection
Valveblock, Tilt
11. Pressure Reducing Valve
12. Check Valve
13. Tilt Left, connection
14. Tilt Valve
15. Tilt Right, connection
Remaining connections
A. Circuit A, connection
B. Circuit B, connection
P. Pump, connection
T. Return to Tank, connection
T2. Return to Tank from Coupler
Only X-systems
T4. Drain, connection
!
For optimum performance and service life, return T1 must be connected to free return. To enable
complete drainage via Drain, a separate return must be connected to the tank via T4.
Schematics and Overwievs for hydraulic as well as electrical systems, in the following pages are meant to
serve mainly as a guide for Troubleshooting.
!
WARNING!
More extensive adjustments and repairs must be done by
an authorized service workshop.
²
R6-R8
R6 - R8
3
1
5
4
6
A
2
8
12
13
14
15
11
B T2 P
T
7
T4
9
10
English
EN
EN -