On / Off function
TILT
HOLD
0,5 sec
#2
#1
Hold function without tiltrotator
PULSE
Hold-to-Run
HOLD
Hold-to-Run
EN
English
Non-variable hydraulic flow
The flow can be locked using switch for
the hold function when the intended level
is reached with roller for the tilt function.
Press and hold the switch for 0.5
seconds.
The next time the switch (Hold) is
pressed the function releases and the
flow ceases.
On/Off control
Switch for the pulse function starts and
closes full flow in one direction.
Switch for the hold function starts and
closes full flow in the other direction.
Activate control with the switch via the
Angles menu.
”On/off Double Feeder” must be
confirmed with OK.
The function is only active in this view.