6
x
Technical data
55
FA ROTEX HPSU compact 308 - 02/2012
Heating system
performance data
Hot water volume without reheating at tapping rate
(8 l/min /12 l/min)
(TKW = 10 °C/TWW = 40 °C/TSP = 50 °C)
l/min
181 / 148
Hot water volume without reheating at tapping rate
(8 l/min /12 l/min)
(TKW = 10 °C/TWW = 40 °C/TSP = 60 °C)
l/min
278 / 245
Hot water volume without reheating at tapping rate
(8 l/min /12 l/min)
(TKW = 10 °C/TWW = 40 °C/TSP = 65 °C)
l/min
343 / 317
Reheating time (Wh) with a draw-off quantity:
l/min
140 l = 5820 Wh (Ø bathtub draw-off quantity)
45
90 l = 3660 Wh (Ø shower draw-off quantity)
30
Pipe connections
Hot and cold water
Inches
1" outer thread
Heating flow and return flow
Inches
1" internal thread
Refrigerant circuit
Number of circuits
1
Pipe connections
Number
2
Liquid line
Type
Inches
Flanged connection
External diameter
Inches
1/4" outer thread
Gas lines
Type
Flanged connection
External diameter
Inches
5/8" outer thread
Operating data
Operating range
Outdoor temperature range
for room heating/cooling
function
Heating (min./max.)
°C
-20 to 25
Cooling (min./max.)
°C
10 to 43
Water heating
Heating (min./max.)
°C
-20 to 35
Noise level
Audibility
dBA
42
Noise pressure
1)
dBA
28
Electrical data:
Voltage supply
Phases
1
Voltage
V
230
Voltage range
V
Voltage ±10%
Frequency
Hz
50
Mains connection
Exterior heat pump unit for HPSU compact
4G
Exterior heat pump unit
3G
Optaionl auxiliary heating Backup heater (BUH)
3G (1-phase) / 5G (3-phase)
Order number
14 15 06
Tab. 6-1
Basic data HPSU compact
1)
With a reference spacing of 1 m.
2)
Upstream of safety protection.
Unit
HPSU compact 308