m
08 February 2019
24-30-00
Initial Issue
Page 18 of 21
Copyright - BRP-Rotax GmbH & CO KG. All rights reserved.
SI-PAC-001
SERVICE INSTRUCTION -
PAC
OPTION B
: Connection as
replacement
of generator B and rectifier regulator B.
See
Fig. 19
See
Fig. 20
Step
OPTION B - Procedure
1
Dis-connect the generator connector (1) from regulator B (2) by pressing on the plas-
tic tab and pulling the connectors apart.
Step
OPTION B - Procedure
2
Insert DEUTSCH dummy plug (1) into open connector on rectifier regulator and
DEUTSCH dummy plug into the open Generator B connector (2).
3
Connect alternator terminal “B” to pin 2 (1) of the fusebox “X3” connector.
4
Ensure that ground stud (2) for regulator rectifier B is connected to airframe ground
with flexible multi-strand wire of min. 4 mm
2
cross section (12 AWG).
1 Connection socket
2 Controller connector
1 Connection socket
2 Controller connector
1 Pin 2
2 Ground stud
10126
10127