08 February 2019
24-30-00
Initial Issue
Page 6 of 21
Copyright - BRP-Rotax GmbH & CO KG. All rights reserved.
SI-PAC-001
SERVICE INSTRUCTION -
PAC
3.1.3) Requirements for correct operation of the integrated rectifier regulator
Fuse
The rectifier regulator must be protected by a slow blowing fuse or circuit breaker. Fuse or circuit
breaker rating must be determined by load, wire size and length.
Load distrubu-
tion
Due to slightly different output voltages of the regulators (alternator and regulator A/B of fuse box)
the power is drawn by the generator with the higher output voltage at low load.
Amperage
See
.
-
Ambient temperature: 20 °C (68 °F)
-
Voltage: constant 13.5 V
-
Tolerance: max.
± 5 %
NOTE:
The speed of the external alternator is 1.18 times the crankshaft speed or 3 times the
propeller speed.
Fig. 2
m
WARNUNG
NOTICE
The current over engine speed graph was determined and is only effective
under the following conditions.
1/min. /
rpm.
2000
3000
4000
5000
6000
7000
8000
n Generator
rpm. alternator
(A)
10
20
30
40
50
1000
1500
2000
2500
n Propeller
rpm. propeller
00547