AYC-FGx4 Family  

Backlit, Waterproof 

Convertible Reader / Controllers 

Instruction Manual 

 

Models: 

AYC-F54 
AYC-F64 
AYC-G54 
AYC-G64 
 
 
 
 
 
 

August 2010 

 

Summary of Contents for AYC-F54

Page 1: ...AYC FGx4 Family Backlit Waterproof Convertible Reader Controllers Instruction Manual Models AYC F54 AYC F64 AYC G54 AYC G64 August 2010 ...

Page 2: ......

Page 3: ...C Fx4 AYC Gx4 Series 14 Selecting Keypad Transmission Format 16 Selecting Proximity Card Transmission Format 23 Changing the Programming Code 24 Changing the Facility Code 25 Return to Factory Default Settings 26 Replacing a Lost Programming Code 26 6 Controller Functionality 27 6 1 Normal Secure and Master Users 27 Normal User 28 Secure User 28 Master User 28 6 2 Modes of Operation 28 Normal Mode...

Page 4: ...ss Code and Door Chime Settings 37 Setting Fail Safe Secure Operation Tamper Siren and Lock Strike Release Time 37 Defining the Auxiliary Input and Output 38 Quick Reference Guide for Auxiliary Mode Setting 40 Detailed Reference Guide 41 Setting the Lockout Feature 45 Enrolling Primary and Secondary Codes 46 Deleting Primary and Secondary Codes 49 Relay Codes Assignment 51 Relay Code Assignment us...

Page 5: ...5T or PS C25TU it functions as a secured controller For information on how the unit functions as a reader see Reader Functionality on page 14 For information on how the unit functions as a controller see Controller Functionality on page 27 All of the units are suitable for indoor or outdoor mounting As a controller the units accept up to 500 users and allow entry via a personal identification numb...

Page 6: ...of Rosslare s secure application appurtenances If a secure application appurtenances is detected then the AYC Fx4 AYC Gx4 are automatically configured as a secure access control unit This is indicated by two short beeps If the secured controller is not detected it is automatically configured as a reader indicated by one short beep 1 3 Box Content Before beginning verify that all of the following i...

Page 7: ...15U Controller Secure Application Appurtenances such as the PS A25T PS C25T or PS C25TU secure controllers This unit connects to the following o Electric lock strike mechanism or a magnetic lock device which implements fail safe power to lock or fail secure power to open functions o Request to Exit REX button normally open type Switch is closed when pressed o Door monitor switch Rosslare accessori...

Page 8: ...LED control input Dry contact N O Tamper output Open collector active low 32mA max sink current Cable distance to host controller Up to 500ft 150 meters using an 18AWG cable Max proximity card read range N A 3 0 inches 80mm N A 3 0 inches 80mm Proximity card modulation N A ASK at 125 KHz N A ASK at 125 KHz Proximity card compatibility N A EM cards N A EM cards Card Transmit format Reader N A 26 bi...

Page 9: ...14 or equivalent Range also depends on electrical environment and proximity to metal 2 1 Key Features The key features for the AYC Fx4 and AYC Gx4 series are Built In Proximity Card Reader 125 KHz ASK Modulation for 64 series only Red backlit keypad Optical back tamper sensor and open controller tamper output Lockout feature on wrong entries Keypad Card Tamper Internal buzzer provides audible inte...

Page 10: ...ance Three User Levels o Normal User o Secure User o Master User Code Search feature that helps make maintaining user codes easier Three Modes of Operation o Normal Mode o Bypass Mode o Secure Mode Request to Exit REX signal from Rosslares secure application appurtenance Chime Bell and Siren features are available with secure application appurtenance Programmable Lock Strike Release Siren and Alar...

Page 11: ...e 1 Drilling mounting holes When the unit is used a reader route the interface cable from the AYC Fx4 AYC Gx4 to the Controller When the unit is used as a secured controller route the interface cable from the AYC Fx4 AYC Gx4 to Rosslares secure application appurtenance A linear type power supply is recommended when using the unit as a controller Screw the AYC Fx4 AYC Gx4 back cover to its mounting...

Page 12: ...Shield Ground Shield Ground Black Ground Data 1 Clock C 1 White Communication Data 0 Data C 2 Green Communication LEDCTL AUX IN Brown LED Control Auxiliary Input Tamper Tamper Purple Tamper If the tamper output is used connect the purple wire to the correct input on the controller when used as a reader or to a zone input of an intruder alarm system when used as a controller Trim and cover all unus...

Page 13: ...ring for the Controller Application using a Dual Relay Secure Application Appurtenance Figure 2 Controller Application Wiring Diagram 1 Wiring diagram 2 below shows the auxiliary output connection using internal power Figure 3 Controller Application Wiring Diagram 2 Rosslare PS X25 Rosslare PS X25 ...

Page 14: ...and AYC Gx4 family manual Page 13 Wiring diagram 3 below shows the auxiliary output connection using the external power Figure 4 Controller Application Wiring Diagram 3 Figure 5 Reader Application Wiring Diagram 4 Rosslare PS X25 ...

Page 15: ...ard or an entered PIN code When the reader is in Transmit Mode the Transmit LED is red and the Program LED is off When a Proximity Card or Keyboard entry is being transmitted the Transmit LED will flash green Keyboard data can be sent via one of eight different Keypad Transmission Formats For more information see Selecting Keypad Transmission Format on page 16 Proximity Cards presented to the read...

Page 16: ...ngle Key 6 Bit Wiegand Rosslare Format Single Key 6 Bit Wiegand with Nibble Parity Bits Single Key 8 Bit Wiegand Nibbles Complemented 4 Keys Binary Facility Code 26 Bit Wiegand 1 to 5 Keys Facility Code 26 Bit Wiegand 6 Keys BCD and Parity Bits 26 Bit Wiegand Single Key 3x4 Matrix Keypad 1 to 8 Keys BCD Clock Data 2 Selecting Card Transmission Format 26 Bit Wiegand Clock Data Wiegand Card PIN 3 Ch...

Page 17: ...Wrong entries may reset the reader back to Transmit Mode While in Programming Mode if no key is pressed for 30 seconds the AYC Fx4 AYC Gx4 will exit Programming Mode and return to Transmit Mode 5 2 1 Selecting Keypad Transmission Format The AYC Fx4 AYC Gx4 has eight different keypad transmission formats to select from Follow the steps below to select the appropriate keypad transmission format that...

Page 18: ...keys in the PIN code Keypad Transmission Format Option Number See the table below to determine the Option Number for the Keypad Transmission Format you wish to select Keypad Transmission Format Option Number Single Key 6 Bit Wiegand Rosslare Format 1 Single Key 6 Bit Wiegand with Nibble Parity Bits 2 Single Key 8 Bit Wiegand Nibbles Complemented 3 4 Keys Binary Facility Code 26 Bit Wiegand 4 1 to ...

Page 19: ...ey press immediately sends 4 bits with 2 parity bits added Even parity for the first 3 bits and odd parity for the last 3 bits 0 0 0000 1 6 1 0110 0 1 0 0001 0 7 1 0111 1 2 0 0010 0 8 1 1000 1 3 0 0011 1 9 1 1001 0 4 1 0100 1 1 1010 0 A in Hexadecimal 5 1 0101 0 1 1011 1 B in Hexadecimal Option 3 Single Key 8 Bit Wiegand Nibbles Complemented Inverts the most significant bits in the message leaving...

Page 20: ...On the fourth key press of the 4 digit PIN code the data is sent across the Wiegand Data lines as binary data in the same format as a 26 Bit Card If the key or the key are pressed during PIN code entry the keypad will clear the PIN code entry buffer generate a beep and is ready to receive a new 4 digit keypad PIN code If the entry of the 4 digits keypad PIN code is disrupted and no number key is p...

Page 21: ...e entry For keypad PIN codes that are 5 digits long on the fifth key press of the 5 digit PIN code the data is sent across the Wiegand Data lines as binary data in the same format as a 26 Bit Card If the key is pressed during PIN code entry or a PIN code greater than 65 535 is entered the keypad will clear the PIN code entry buffer generate a beep and is ready to receive a new 5 digit keypad PIN c...

Page 22: ...pad PIN code EP AAAA BBBB CCCC DDDD EEEE FFFF OP Where EP Even parity for first 12 bits OP Odd parity for last 12 bits A The first key entered D Fourth key entered B Second key entered E Fifth key entered C Third key entered F Sixth key entered Option 7 Single Key 3x4 Matrix Keypad MD P64 This unique mode is intended to let the host controller scan the AYC Fx4 AYC Gx4 keypad while still keeping th...

Page 23: ...e to eight digits long The PIN code length is selected while programming the reader for Option 8 The reader will transmit the data when it receives the last key press of the PIN code The data is sent across the two data output lines as binary data in Clock Data format If the key or the key are pressed during PIN code entry the keypad will clear the PIN code entry buffer generate a beep and is read...

Page 24: ... System returns to Transmit Mode You will hear three beeps The Program LED will turn off The Transmit LED will turn red Proximity Card Transmission Format Option Number Option 1 26 Bit Wiegand Option 2 Clock Data Option 3 Wiegand Card PIN Wiegand Card PIN Transmission Format This unique mode is intended to let host controllers get card and keypad data simultaneously This option overrules the selec...

Page 25: ... AYC Gx4 output card data in 26 Bit Wiegand with the following keypad data in 26 Bit Wiegand format Card Data EP AAAA AAAA AAAA BBBB BBBB BBBB OP Where EP Even parity for first 12 A bits OP Odd parity for last B 12 bits PIN Data EP 0000 AAAA BBBB CCCC DDDD EEEE OP Where A The first key entered D Fourth key entered B Second key entered E Fifth key entered C Third key entered EP Even parity for firs...

Page 26: ...ory default 4 digit Programming Code is 1234 5 2 4 Changing the Facility Code 1 Enter Programming Mode 2 Press 4 to enter Menu 4 The Transmit LED will turn red 3 Enter the new 3 digit code you wish to set as the Facility Code 4 System returns to Transmit Mode You will hear three beeps The Program LED will turn off The Transmit LED will turn red Note Facility Code can be in the range of 000 to 255 ...

Page 27: ...and the controller will return to Normal Mode If the Programming Code is invalid you will hear a long beep and the controller will return to Normal Mode without erasing the memory of the controller 5 2 6 Replacing a Lost Programming Code In the event that the Programming Code is forgotten the AYC Fx4 AYC Gx4 may be reprogrammed in the field using the following instructions 1 Remove power from the ...

Page 28: ... Gx4 accepts up to 500 users and provides entry via the use of PIN codes and or Proximity cards Each user is provided with two code memory slots Memory Slot 1 Primary Code and Memory Slot 2 Secondary Code The pin code length has several options The pin code length can be a set number of 4 5 or 6 digits or it can be a 4 8 digits option When choosing the 4 8 digit option please note that you should ...

Page 29: ...heir Primary and Secondary Codes in order to gain entry 6 1 3 Master User A Master User must have both Primary and Secondary Codes programmed with the same code The Master User can gain access during any mode of operation by presenting their PIN code and or Proximity card once to the controller The Master User is convenient but is less secure than a Secure User 6 2 Modes of Operation The AYC Fx4 A...

Page 30: ...access the premises during the Secured Mode A Secure User must enter their Primary and Secondary Codes to gain entry After entering their Primary Code the Door LED will flash green for 10 seconds during which the Secondary Code must be entered A Master User only needs to present their code once to gain entry 6 2 4 Changing the Modes of Operation Changing from Normal Mode to Secure Mode The default...

Page 31: ...code Mode LED will flash Orange 2 Press the key to confirm the mode change Mode LED will turn orange Changing from Bypass Mode to Normal Mode See Changing the Normal Bypass Code and Door Chime Settings on page 37 to create modify the Normal Bypass code 1 Enter the 4 digit Normal Bypass code Mode LED will flash green 2 Press the key to confirm the mode change Mode LED will turn green Mode Transmit ...

Page 32: ...e the unit is forcibly opened or it is removed from the wall a tamper event is triggered A tamper output opens sending a signal to the connected Alarm system purple wire the event closes when the tamper is closed case is re closed or re attached to the wall The tamper event can also activate the auxiliary output if the controller is in Auxiliary Mode 3 Refer to the Quick Reference Guide for Auxili...

Page 33: ...ton is pressed the door will be unlocked until the REX Button is released plus the Lock Strike Release Time In this case the Lock Strike Relay only begins its count down once the REX Button has been released 6 8 Secure Application Appurtenances Rosslares secure application appurtenances are designed for use with Rosslare s secured series stand alone access control units including AYC FX4 AYC GX4 I...

Page 34: ...Fx4 AYC Gx4 Menus It also shows of all the AYC Fx4 AYC Gx4 default factory codes and settings 6 9 1 Programming Menu Menu No Menu Description Default 4 digit 5 digit 6 digit 4 8 digits 1 Changing Lock Strike Code 2580 25802 258025 25802580 2 Changing Auxiliary Code 0852 08520 085208 08520852 3 Changing Program Code 1234 12341 123412 12341234 4 Changing Normal Secure Code 3838 38383 383838 38383838...

Page 35: ...will turn off and the Mode LED will return to Normal 2 Wrong entries may reset the controller back to Normal mode 3 While in Programming mode if no key is pressed for one minute the AYC Fx4 AYC Gx4 will exit Programming mode and return to Normal mode 6 9 4 Changing Lock Strike Code The Lock Strike Code is mainly used as a method to quickly test the Lock Strike Relay during installation When the fi...

Page 36: ...When the first user is added to the controller the default Auxiliary Code will automatically be deleted Once the code is programmed again it will not be deleted with the entry of additional User Codes 1 Enter Programming mode 2 Press 2 to enter Menu 2 The Mode LED will turn orange 3 Enter the new code you wish to set as the auxiliary Code 4 System returns to Normal mode You will hear three beeps N...

Page 37: ...de is 1234 6 9 7 Changing the Normal Secure Code 1 Enter Programming mode 2 Press 4 to enter Menu 4 The Mode LED will flash red 3 Enter the new code you wish to set as Normal Secure Code 4 System returns to Normal mode You will hear three beeps Note Code 0000 will erase the Normal Secure Code This code is disabled in case the Auxiliary Input is set to toggle between Normal and Secure access modes ...

Page 38: ...nable Bypass Code and disable the door chime Enter any code ending with 0 d Enable Bypass Code and enable the door chime Enter a code not ending with 0 4 System returns to its normal mode You will hear three beeps The Door LED will turn off The Mode LED will turn green 6 9 9 Setting Fail Safe Secure Operation Tamper Siren and Lock Strike Release Time 1 Enter Programming mode 2 Press 6 to enter Men...

Page 39: ... 0312 means Fail Secure Operation a 3 minute Siren and a 12 second Lock Strike release time 4 System returns to its normal mode You will hear three beeps The Door LED will turn off The Mode LED will turn green Note Default value is 0004 which corresponds to Fail Secure operation no siren and 4 seconds Lock Strike release time 6 9 10 Defining the Auxiliary Input and Output The default auxiliary set...

Page 40: ...ode defines the function of the Auxiliary Input Auxiliary Settings Each of the Auxiliary Modes has a two digit setting that affects how the Auxiliary Mode functions 4 System returns to its normal mode You will hear three beeps The Door LED will turn off The Mode LED will turn green The Second digit defines Auxiliary Input function while the Third and Fourth digits may have no meaning or otherwise ...

Page 41: ...00 Aux relay toggle 2 Normal Secure switch Star button N O 01 to 99 Aux relay release time 00 Aux relay toggle 3 Normal Secure switch Tamper event N C 01 to 99 Aux relay release time 00 Aux relay tamper activated 4 Normal Secure switch Direct shunt N O 01 to 99 Shunt time 5 Door Monitor Shunt N C 01 to 99 Maximum shunt time 6 Door Monitor Forced door N C 01 to 99 Forced delay 7 Door Monitor Door a...

Page 42: ...o be attached to the REX pushbutton for the second door Door Monitor input feature for the second door is not enabled when using this mode Auxiliary Mode 1 Auxiliary input function Toggles normal secure modes Auxiliary output activated by Valid user code Auxiliary code E g In auxiliary mode 1 the controller can function as a two door controller The auxiliary relay is to be attached to the lock on ...

Page 43: ...Toggles normal secure modes Auxiliary output activated by Alarms E g In auxiliary mode 3 the auxiliary output is activated if the controller is tampered that is if the case is forcibly opened or removed from the wall The auxiliary input can switch the mode of operation of the controller between normal and secure mode By connecting a switch timer or alarm system output to the auxiliary input the co...

Page 44: ...uxiliary relay will open if the door closes the auxiliary relay will close When a valid code is entered a count down for maximum shunt time as defined by the auxiliary setting begins if the door is not closed before the maximum shunt time the alarm will be triggered Auxiliary Mode 6 Auxiliary input function Door Monitor Auxiliary output activated by Forced entry E g In auxiliary mode 6 the control...

Page 45: ... the controller will activate the auxiliary relay The auxiliary setting defines the door ajar time Auxiliary Mode 8 Auxiliary input function Green LED control Auxiliary output activated by Valid user code Auxiliary code E g In auxiliary mode 8 the controller can function as a two door controller and also provide indicator functionality control The auxiliary relay is connected to the lock on the se...

Page 46: ... the Door indicator LED The indicator LED will not be lit when A valid code is entered While in secure mode when waiting for a secondary code 6 9 13 Setting the Lockout Feature In case the controller is presented with wrong codes consecutively several times the unit goes into lockout mode When a lockout occurs the controller keypad and reader are locked so no codes can be entered until the set loc...

Page 47: ... Primary Codes must be unique i e one user s Primary Code may not be the same as other users Primary Code Primary Codes cannot be the same as any system codes such as the Normal Secure Code or Lock Strike Code Users who hold a Primary Code can gain entry only during Normal mode Secondary Codes Secondary Codes can only be enrolled to User Slot that already has a Primary Code enrolled but no Seconda...

Page 48: ...lled but the Secondary Code is not See Enrolling Secondary Codes using the Code Search Method on page 48 Enrolling Primary and Secondary Codes using the Standard Method 1 Enter the Programming Mode 2 Press 7 to enter Menu 7 The Door LED will turn orange 3 Enter the 3 digit User Slot number between 001and 500 that you wish to enroll a Primary or Secondary code to For example User Slot 003 represent...

Page 49: ... the key twice and the controller will return to Normal mode Enrolling Secondary Codes using the Code Search Method The Code Search feature enables you to quickly enroll a Secondary Code to a user who already has a Primary Code 1 Enter the Programming Mode 2 Press 7 to enter Menu 7 The Door LED will turn orange 3 Enter 000 as the 3 digit User Slot number The Door LED will flash orange The controll...

Page 50: ...o delete Primary and Secondary codes the Standard Method and the Code Search Method When deleting a User Slot both the Primary Code and the Secondary code are erased Deleting Primary and Secondary Codes using the Standard Method 1 Enter the Programming Mode 2 Press 8 to enter Menu 8 The Door LED will turn orange The Mode LED will turn red 3 Enter the 3 digit User Slot code you wish to delete The M...

Page 51: ...ogramming Mode 2 Press 8 to enter Menu 8 The Door LED will turn orange The Mode LED will turn red 3 Enter 000 as the 3 digit User Slot number The Mode LED will turn red The Door LED will flash orange The controller is now waiting for the Primary Code of the User you want to delete 4 Enter the 4 8 digit PIN Code of the Primary Code belonging to the user you want to delete The Mode LED will flash re...

Page 52: ...y relay instead or operate both the Lock strike and auxiliary relay Assignment of such codes is achievable for any valid user code entered in the controller There are two methods to assign relay codes to users a standard method and a search method Relay Code Assignment using Standard Method 1 Enter the programming mode 2 Depress 9 to enter Menu 9 The Mode LED will turn green The Door LED will turn...

Page 53: ...orange The controller is now waiting for the primary code of the user 4 Enter the primary code belonging to the user The Mode LED will flash green 5 Enter the assignment digit for the current user slot 1 will activate the Lock Strike relay only deafult 2 will activate the Auxiliary relay only 3 will activate the Lock Strike and Auxiliary relays If the assignment digit is valid three beeps will be ...

Page 54: ... c 06 Returns to factory defaults and sets a 6 digit code d 08 Returns to factory defaults and sets a 4 8 digit code Note When choosing the 4 8 option please note that you should either enter zeros before the code or press pound at the end for example if your code is 12345 enter either 00012345 or 12345 Both the Mode and Door LEDs will flash red 3 Enter your 4 8 digits Programming Code If the Prog...

Page 55: ...ault code based on the PIN code length you chose see Programming Menu on page 33 before the controller reverts to the existing code 6 9 20 Replacing a Lost Normal Secure Code Note The AYC Fx4 AYC Gx4 must be in Secure Mode otherwise this will not work Make sure that the Mode LED is red before proceeding 1 Remove power from the Power Supply Unit 2 Press the REX Button on the Power Supply Unit 3 App...

Page 56: ...e with the terms of this warranty Unless otherwise requested by ROSSLARE ENTERPRISES LTD AND OR SUBSIDIARIES representative return of the failed product s is not immediately required If ROSSLARE has not contacted the Customer within a sixty 60 day holding period following the delivery of the warranty claim Customer will not be required to return the failed product s All returned Product s as may b...

Page 57: ...h the Product if Product disassembled or repaired in such a manner as to adversely affect performance or prevent adequate inspection and testing to verify any warranty claim ROSSLARE does not warrant the installation maintenance or service of the Product Service life of the product is dependent upon the care it receives and the conditions under which it has to operate In no event shall Rosslare be...

Page 58: ...ted States and Canada 1600 Hart Court Suite 103 Southlake TX USA 76092 Toll Free 1 866 632 1101 Local 1 817 305 0006 Fax 1 817 305 0069 E mail support na rosslaresecurity com Europe Global Technical Support Training Center HaMelecha 22 Rosh HaAyin Israel 48091 Tel 972 3 938 6838 Fax 972 3 938 6830 E mail support eu rosslaresecurity com South America Pringles 868 1640 Martinez Buenos Aires Argentin...

Page 59: ......

Page 60: ...0706 0960124 02 www rosslaresecurity com ...

Reviews: