VLT
®
8000 AQUA
■
Quick Menu
The QUICK MENU key gives access to 12 of the
most important setup parameters of the drive. After
programming, the drive will, in many cases, be ready
for operation. The 12 Quick Menu parameters are
shown in the table below. A complete description
of the function is given in the parameter
sections of this manual.
Quick Menu
Parameter
Description
Item Number
Name
1
001 Language
Selects language used for all displays.
2
102 Motor Power
Sets output characteristics of drive based on kW size
of motor.
3
103 Motor Voltage
Sets output characteristics of drive based on voltage
ofmotor.
4
104 Motor Frequency
Sets output characteristics of drive based on nominal
frequency of motor. This is typically equal to line
frequency.
5
105 Motor Current
Sets output characteristics of drive based on nominal
current in amps of motor.
6
106 Motor Nominal Speed
Sets output characteristics of drive based on nominal
full load speed of motor.
7
201 Minimum Frequency
Sets minimum controlled frequency at which motor
will run.
8
202 Maximum Frequency
Sets maximum controlled frequency at which motor
will run.
9
206 Ramp Up Time
Sets time to accelerate motor from 0 Hz to nominal
motor frequency set in Quick Menu Item 4.
10
207 Ramp Down Time
Sets time to decelerate motor from nominal motor
frequency set in Quick Menu Item 4 to 0 Hz.
11
323 Relay1 Function
Sets function of high voltage Form C relay.
12
326 Relay 2 Function
Sets function of low voltage Form A relay.
■
Parameter Data
Enter or change parameter dataor settings in
accordance with the following procedure.
1.
Press Quick Menu key.
2.
Use ‘+
’
and ‘-
’
keys to find parameter
you choose to edit.
3.
Press Change Data key.
4.
Use ‘+
’
and ‘-
’
keys to select correct parameter
setting. To move to a different digit within
parameter, use < and > arrows.
Flashing cursor
indicates digit selected to change.
5.
Press Cancel key to disregard change, or press
OK key to accept change and enter new setting.
Example of Changing Parameter Data
Assume parameter 206,
Ramp Up Time,
is set at 60
seconds. Change the ramp up time to 100 seconds
in accordance with the following procedure.
1.
Press Quick Menu key.
2.
Press ‘+
’
key until you reach Parameter
206,
Ramp Up Time.
3.
Press Change Data key.
4.
Press < key twice – hundreds digit will flash.
5.
Press ‘+
’
key once to change hundreds digit to ‘1.
’
6.
Press > key to change to tens digit.
7.
Press ‘-
’
key until ‘6
’
counts down to ‘0
’
and
setting for
Ramp Up Time
reads ‘100 s.
’
8.
Press OK key to enter new value into
drive controller.