Consecutive Rejects Error
Figure 6-9:
6.4
Line stop
The control system provides a signal that can stop the production line if there are errors on
the system.
The signal is sent to the STATUS connector shown in
Figure 2-2
. The connection is a volt-
free contact and can be configured in
Normally Closed
(NC) and
Normally Open
(NO) from a
customer supplied 24 V.
Line Stop Plug Pin Numbering
Table 6-1:
24 V line
0 V line
Normally Closed (NC)
1
2
Normally Open (NO)
3
2
The overall system is high when healthy (green light) and low when unhealthy (red light).
Operation
Reference Manual
29
Summary of Contents for CT4215
Page 1: ...Reference Manual 00809 0100 4245 Rev AB July 2018 Rosemount CT4215 Leak Detection System ...
Page 12: ...Contents ii Rosemount CT4215 ...
Page 28: ...Installation 16 Rosemount CT4215 ...
Page 30: ...Startup 18 Rosemount CT4215 ...
Page 44: ...Operation 32 Rosemount CT4215 ...
Page 50: ...Maintenance 38 Rosemount CT4215 ...
Page 54: ...Troubleshooting and diagnostics 42 Rosemount CT4215 ...