Concentration Tab
Figure 6-3:
Figure 6-3
shows the
Concentration
tab with one leaking package passing through. When
the blue line reaches the upper threshold (red line), the sensor sends a rejection signal to
the PLC and then the rejection solenoid to remove the faulty pack from the line. The lower
threshold is typically approximately 80 percent of the upper threshold and prevents the
system from missing a marginal leak.