PLC Configuration Parameters
Table 6-2:
Parameter name
Description
Range
Pack Length
The length of time a pack takes to pass
the input gate. This timer is a de-
bounce to prevent double counting of
uneven packs.
0 - 2000 ms
Measurement Start
The delay between the pack passing
the input gate and the sensor count-
ing it IN and beginning analysis.
0 - 9000 ms
Measurement End
The delay between the pack being
counted in and the sensor finishing
analysis. This ensures complete in-
spection from leading edge to trailing
edge. This also generates the pack
OUT count on the software screen.
0 - 10000 ms
Reject Delay
The time between the bag being
counted OUT and the rejection mech-
anism.
60000 ms (1 minute)
Reject Duration
The length of time for which the rejec-
tion solenoid is open for rejection.
10000 ms
Operation
Reference Manual
31