6
Operation
The packaged Leak Detection System is designed to run autonomously with minimal user
interaction required. After the startup procedure in
Chapter 4
, the system needs only a
green light to run.
There are up to three components mounted onto the packaged production line. The
layout of the line is shown schematically in
Figure 6-1
.
Schematic Layout of the System On Line
Figure 6-1:
The packs flow on the schematic above from left to right. The packs pass through the input
gate which is located before the sample head. A space of at least 1 in. (2.5 cm) is required
between packs in order to ensure correct counting and rejection. A space of at least 6 in.
(15.2 cm) is advised for best operation.
The sample head then analyzes the pack/container.
The reject mechanism safely removes faulty containers from the production line without
the need to stop the line. The distances between the components is set at the time of
install and is determined by the speed of the production line.
Operation
Reference Manual
21