![Rosemount 3144 Manual Download Page 106](http://html1.mh-extra.com/html/rosemount/3144/3144_manual_1487449106.webp)
Rosemount Models 3144 and 3244MV Smart Temperature Transmitters
C-8
WARNING–This
address already being
used
Another transmitter is already using the entered multi-drop address.
Enter a new address.
WARNING–This will
erase work reg
Data in the Working Register will be replaced with data from
another location.
WARNING–Xmtr/268
not in communication
Model 268 did not get answer from transmitter:
• Check connections
• Check that power is reaching transmitter
• Check for minimum 250 ohms resistance in loop
WARNING–Xmtr in
output mode
During start-up and restart, the transmitter milliamp output does not
reflect the process variable. Press F4.
WARNING–Xmtr is not
communicating
Model 268 did not get answer from transmitter:
• Check connections
• Check that power is reaching transmitter
• Check for minimum 250 ohms resistance in loop
WARNING–268 does
not know this Xmtr
Model 268 recognizes a Rosemount transmitter in the loop but
cannot communicate with it. The message usually indicates a
software revision level incompatibility between the Model 268 and
the transmitter.
XMTR Mem diff than
WORK Regs–XMTR not
changed
Data in the Working Register and in the transmitter have different
unique identifiers. The Model 268 was probably connected to
different transmitter without RESTART or power-off/power-on
sequence. Press RESTART to erase the Working Register or save
the Working Register to the Off-line Memory and download to the
proper transmitter at a later time.
Xmtr Security: On–
XMTR will not accept
changes to Memory
Transmitter lockout security switch is ON and electronics will not
accept changes to configuration. Reset switch to remove this
message.
Xmtr still busy
Transmitter is running a computational or diagnostic routine and
cannot respond to the Model 268 instructions. Press the
PREVIOUS FUNCTION key to cancel.
XXXX=YYYY ERR–
Illegal value
Unacceptable value entered.
XXXX=YYYY ERR–Out
of range
The difference between LRV and URV is greater than the maximum
span allowed by the transmitter. Enter a new value.
XXXX=YYYY ERR–
Span too small
The difference between LRV and URV is less than the minimum
span allowed by the transmitter. Enter a new value.
XXXX=YYYY ERR–Valu
was too hi
See instructions for the selected parameter. Enter a new value that
is acceptable.
XXXX=YYYY ERR–Valu
was too lo
See instructions for the selected parameter. Enter a new value that
is acceptable.
XXXX=YYYY ERR–LRV
too hi
LRV was set to a value above the URL. Enter a new value.
XXXX=YYYY ERR–LRV
too lo
LRV was set to a value above the LRL Enter a new value.
XXXX=YYYY ERR–LRV
& URV out limits
Both the LRV and URV were outside the sensor’s range limits. Enter
a new value.
XXXX=YYYY ERR–URV
too hi
URV was set to a value above the URL. Enter a new value.
XXXX=YYYY ERR–URV
too lo
URV was set to a value below the LRL. Enter a new value.
XXXX=YYYY ERR–268
data err
Transmitter cannot interpret a Model 268 inquiry. Make note of
conditions and keystrokes leading to failure, and contact
Rosemount Service Center.
268 Failure–No. 2
Model 268 has detected bug in its software. Make note of conditions
and keystrokes leading to failure, and contact Rosemount Service
Center.
268 Test: FAIL
Model 268 is not functioning properly. Turn OFF and contact
Rosemount Service Center.
Message