C-7
Model 268 SMART FAMILY Interface
Errors Detected–XMTR
Mem not changed
Transmitter did not accept data because it contained non-
permissible values. Data errors must be corrected and the data sent
again.
FAILURE–Electronics
The transmitter electronics has experienced a component or
software failure. Contact Field Service Center.
Gen failure–No. 1
Transmitter has given improper response to Model 268. Perform a
transmitter test. If OK, make note of conditions and keystrokes
leading to failure, and contact Rosemount Service Center.
Making changes
permanent–PLEASE
WAIT
Data is being sent to transmitter and transmitter is accepting the
data.
No data modified to
send
Data with no changes is being sent. Press F4 to continue.
No data saved in OFLN
Mem
There are no data in the Off-line Memory to review.
No data saved in SAFE
Mem
There are no data in the Safe Memory to review.
Ofln Mem not
compatible with WORK
REGS–Data not
transferred
The data stored in Off-line Memory and Working Register are from
different kinds of transmitters, or the Off-line Memory is empty.
Press F4, REVIEW, F2 to see the data in Off-line Memory and
connect the Model 268 to similar transmitter.
SAFE Mem from diff
Xmtr than WORK
REGS–Data not
transferred
Data in the Safe Memory and Working Register are from different
transmitters. Press F4, REVIEW, F1 and find the transmitter serial
number. Connect the Model 268 to the transmitter with that serial
number and press RESTART.
SAFE Mem not
compatible with WORK
REGS–Data not
transferred
The unique identifier in the Safe Memory and the transmitter are
different. Press F4, REVIEW, F1 to see the data in the Safe Memory.
Connect the Model 268 to the matching transmitter and press
RESTART.
WARN–Used nearest
legal table value
The value entered has too many decimal places. The Model 8800
defaults to the closest value available.
WARN–Value at limit
reverse direction
The entered value is beyond the upper or lower limit. Adjust to a
value within the limits.
WARN–Value entered is
illegal, re-enter
The Model 268 will not accept the entered value. Enter an
acceptable value (see relevant section in manual).
WARN–Value out of
limits, altered by 268,
re-check data
The Model 268 could not store the entered value so it changed to
the maximum allowable value. Check the new value.
WARNING–Analog
output outside range
points
Process variable information is outside the 4–20 mA range points.
Rerange the transmitter.
WARNING–Control
loop should be in
manual
Before sending the data that could affect the 4–20 mA output signal,
set the loop to manual control. After it is set, press F4.
WARNING–Data
transmission error
Previous communication between Model 268 and the transmitter
was not successful. If this message appears repeatedly, check the
loop for a source of noise that could corrupt the signal.
WARNING–Loop may
be returned to auto
After completing a communication that required the loop to be set in
manual, you may return the loop to automatic control.
WARNING–Match xmtr
S/N to nameplate S/N
Check to be sure that the entered transmitter serial number is the
same as that on the transmitter nameplate.
WARNING–Not on line
The key you have pressed is not applicable for off-line configuration
tasks.
WARNING–Process
has been aborted
Indicates that the self-test has been aborted by pressing any key.
WARNING–PV out of
range
Process variable information of the transmitter exceeds sensor
limits. Check flow rate. If it is too high, correct the flow. If not, the
sensor has a malfunction and needs to be replaced.
WARNING–Some of the
changes were not
saved in the xmtr mem
Transmitter did not receive all configuration changes. Note
differences in configuration data and reconfigure the transmitter
accordingly.
Message